background image

 

 
NOTES 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DC-X Series

Page 1: ...User Manual Operating Instructions DC X Fridges CARAVAN MARINE RV OFFGRID User Manual and 12 24V Fridge Freezer Product Specifications Read user manual before operating your fridge freezer DC 85X DC 130X ...

Page 2: ...mpleted by a suitably trained professional only POWER SUPPLY Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only The compressor will automatically detect which voltage is present adjust accordingly If you are using a generator or other power supply the output must be a pure sine wave Any fluctuations in generator current may damage the compressor WIRING For op...

Page 3: ... KIT The mounting kit is first affixed to the side and top of the fridge cabinet using the screws provided Once the fridge has been connected to the power supply and moved into its final position the mounting kit can be affixed to the front of the cavity OPERATING THE FRIDGE THERMOSTAT The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE ...

Page 4: ...en opening or closing the freezer door if ice has been allowed to accumulate in this area Keep the door of the fridge ajar when the fridge is not in use to allow fresh air to circulate inside the fridge compartment DEFROSTING Defrosting needs to be carried out when the ice layer reaches a thickness of 5mm Turn off the power to the fridge and move your food and beverages to another cool place Do no...

Page 5: ...wards so that the plastic latch is just touching Reaffix in this position See diagram below CORRECT 0 1MM GAP INCORRECT 2MM GAP RUBBER SEALS 1 There are magnets inside the rubber seal which pull towards the metal fridge cabinet to keep it airtight 2 After you have adjusted your door latch check to see that the rubber seal is making contact with the fridge cabinet on all 4 sides If there is even a ...

Page 6: ...wiring checked by an electrician when under a 10 A load TROUBLESHOOTING Check Correct power supply The voltage to the compressor is still 12V when a 10 A load is placed on the wire The fan is operating The polarity of the connections are correct There is adequate ventilation to the rear of the fridge The fuse is not blown The rubber door seal is touching the fridge cabinet all the way around on al...

Page 7: ......

Page 8: ......

Page 9: ...Exterior Ventilation Interior Ventilation Option 1 Interior Ventilation Option 3 min 200cm2 min 40mm min 40mm min 40mm min 40mm min 40mm Interior Ventilation Option 4 Interior Ventilation Option 2 min 200cm2 min 150mm min 150mm ...

Page 10: ...NOTES ...

Page 11: ...shipping charges related to returning the repaired product to the customer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bus...

Page 12: ...For after sales service and enquiries please contact Bushman Fridges 3 Contour Close Research VIC 3095 03 9437 0737 info bushman com au ...

Reviews: