3
Installation
Positioning & electrical connection
Customer Helpline
0845 600 4632
Advice for installer
IMPORTANT
- The appliance should be installed,
regulated and adapted to function with other
types of gas by a Gas Safe Registered Engineer.
Failure to comply with this condition will render
the guarantee invalid.
IMPORTANT
- The appliance must be installed in
compliance with regulations in force.
IMPORTANT
- Installation technicians must
comply to current laws in force concerning
ventilation and the evacuation of exhaust gases.
IMPORTANT
- Always disconnect the gas supply
from the appliance before carrying out any
maintenance operations or repairs.
IMPORTANT
- The appliance must be housed in
heat-resistant units.
IMPORTANT
- These tops are designed to be
embedded into kitchen fixtures measuring 600
mm in depth.
IMPORTANT
- The walls of the units must not be
higher than work top and must be capable of
resisting temperatures of 60 °C above room
temperature.
IMPORTANT
-
Do not
install the appliance near
inflammable materials (eg. curtains).
IMPORTANT
-
IMPORTANT
-
IMPORTANT
-
Location
The appliance may be installed in
a kitchen or kitchen/diner, but not in a room or
space containing a bath or a shower.
The appliance must not be
installed in a bed-sitting room of less than 20 m
3
.
The appliance is designed and
approved for domestic use only and should not
be installed in a commercial, semi commercial or
communal environment. Your product will not be
guaranteed if installed in any of the above
environments and could affect any third party or
public liability insurances you may have.
Ventilation requirements
3
For rooms with a volume of less than 5 m -
2
permanent ventilation of 100 mm free area will
be required.
3
For rooms with a volume of between 5 m and 10
2
3
m a permanent ventilation of 50 cm free area
will be required unless the room has a door which
opens directly the outside air in which case no
permanent ventilation is required.
3
For rooms with a volume greater than 10 m - no
permanent ventilation is required.
NB. Regardless of room size, all rooms
containing the appliance must have direct access
to the outside air via an open window or
equivalent.
Electrical connection
IMPORTANT
- Electrical connections must be
carried out by a suitably qualified person and
in accordance with all relevant local building
and installation regulations.
1. This appliance is fitted with fused plug which
should be inserted into a suitable mains
socket.
2. It is recommended that the mains socket is
located behind the appliance and is
switched on and off via a separate switched
Fused Connection Unit (FCU).
3. It is recommended that the switched FCU is
located adjacent to the appliance within a
maximum distance of 2m. The switched
FCU must not be located above the
appliance but should be easily accessible in
case of an emergency.
Installation
Customer Helpline
0845 600 4632
CAUTION! This appliance must only be installed by a Gas Safe Registered Engineer.