Electrical Connection | 6
Instruction Manual R5 RA 0165-0305 D_EN_en
21 | 44
Delta connection, multi-voltage motor with 12
pins (middle voltage):
4
4
4
6.5
Electrical Connection of the Monitoring Devices
NOTE
In order to prevent potential nuisance alarms, Busch recommends that the control system is
configured with a time delay of at least 20 seconds.
6.5.1
Wiring Diagram Level Switch (Optional)
Part no.:
0652 567 576
Connector:
M12x1, 4-pin
Electrical data:
U = 10 – 30 V DC
I consumption : <15 mA
I output max : 150 mA
Switch point:
Pin 1 = low level
1 = Brown: 24V DC
3 = Blue: Supply 0V DC
4 = Black: Signal low level
NOTE:
For this device, the recommended time delay to
prevent nuisance alarms can be up to 240
seconds.
6.5.2
Wiring Diagram Temperature Switch "Oil" (Optional)
Part no.:
0651 566 632
Connector:
M12x1, 4-pin
Electrical data:
U =
≤
250 V AC/DC (50/60 Hz) ; I =
≤
1 A
Switch point:
T
1
pin 1 + 2 = 110 °C*
T
2
pin 3 + 4 = 130 °C*
1
2
4
3
2
1
T
1
4
3
T
2
1 = Brown ; 2 = White ;
3 = Blue ; 4 = Black
*
The switch point value depends on the oil type, see
40].