13 | Technical Data
28 | 32
Instruction Manual R5 RA 0063 F5K_EN_en
13
Technical Data
RA 0063 F 5K
Nominal pumping speed (50Hz / 60Hz)
m³/h
63 / 76
Ultimate pressure (without gas ballast valve)
hPa (mbar)
abs.
0.1 … 0.5
►
see nameplate (NP)
Ultimate pressure (with gas ballast valve)
hPa (mbar)
abs.
0.5 … 1.5
Nominal motor speed (50Hz / 60Hz)
min
-1
1500 / 1800
Nominal motor rating (50Hz / 60Hz)
kW
2.0 / 2.4
Power consumption at 100 mbar (50Hz / 60Hz) kW
1.3 / 1.5
Power consumption at ultimate pressure
(50Hz / 60Hz)
kW
0.7 / 0.8
Noise level (EN ISO 2151) (50Hz / 60Hz)
dB(A)
64 / 67
Water vapor tolerance max. (with gas ballast
valve)
hPa (mbar)
abs.
40
Water vapor capacity (with gas ballast valve)
kg / h
1.8
Operating temperature (50Hz / 60Hz)
°C
84 / 92
Ambient temperature range
°C
5 ... 40
Ambient pressure
Atmospheric pressure
Oil capacity
l
1.0
Weight approx.
kg
52