Technical Data | 13
Instruction Manual PUMA WP 0250-2000 D_EN_en
29 | 36
13
Technical Data
WP 0250 D4
WP 0500 D2
WP 0500 D4
WP 0700 D2
Nominal pumping speed
(50Hz / 60Hz)
m³/h
250 / 300
500 / 600
500 / 600
700 / 840
Max. differential pressure hPa
(mbar)
80
50
80
50
Nominal motor rating
(50Hz / 60Hz)
kW
1.1 / 1.5
2.2 / 3.0
2.2 / 2.4
3.5 / 4.8
Nominal motor speed
(50Hz / 60Hz)
min
-1
1500 / 1800
3000 / 3600
1500 / 1800
3000 / 3600
Sound pressure level*
(50Hz / 60Hz)
dB(A)
On request
59 / 63
On request
60 / 64
Incertainty KpA
dB
3
Ambient temperature
range
°C
5 … 40
Max. gas inlet
temperature
°C
200
(P <10 hPa, staging ratio of 4)
Relative humidity
at 30°C
90%
Oil capacity
l
1.4 (vertical gas flow) / 0.9 (horizontal gas flow)
Oil capacity (Oiler)
l
0.26
Weight approx.
kg
150
150
200
200
*
according to
DIN EN ISO 2151.
Operation under ultimate pressure. Pressure level above 10 mbar may
result in higher noise levels.
WP 1000 D2
WP 1000 D4
WP 1250 D2
WP 2000 D2
Nominal suction capacity
(50Hz / 60Hz)
m³/h
1000 / 1200
1010 / 1220
1295 / 1555
2020 / 2435
Max. differential pressure hPa
(mbar)
50
80
50
50
Motor nominal rating
(50Hz / 60Hz)
kW
3.5 / 4.8
5.5 / 6.6
4.3 / 5.2
5.5 / 7.0
Motor nominal speed
(50Hz / 60Hz)
min
-1
3000 / 3600
1500 / 1800
3000 / 3600
3000 / 3600
Sound pressure level*
(50Hz / 60Hz)
dB(A)
60 / 64
On request
On request
61 / 65
Incertainty KpA
dB
3
Ambient temperature
range
°C
5 … 40
Max. gas inlet
temperature
°C
200
(P <10 hPa, staging ratio of 4)
Relative humidity
at 30°C
90%
Oil capacity
l
1.4 (vertical gas flow) / 0.9 (horizontal gas
flow)
2.7 (vert. gas
flow / 1.7
(hor. gas
flow)
Oil capacity (Oiler)
l
0.26
Weight approx.
kg
200
350
250
350
*
according to
DIN EN ISO 2151.
Operation under ultimate pressure. Pressure level above 10 mbar may