BUSCH PANDA WV 1200 A Instruction Manual Download Page 36

Busch
Vacuum Solutions

With a network of over 60 companies in more than 40 countries and agencies worldwide,
Busch has a global presence. In every country, highly competent local personnel delivers
custom-tailored support backed by a global network of expertise. Wherever you are.
Whatever your business. We are there for you.

Local representatives and distributors

Busch companies and Busch employees

Busch production site

www.buschvacuum.com

0870572562 | A0006_en-US

Summary of Contents for PANDA WV 1200 A

Page 1: ...Get technical data instruction manuals service kits PANDA Vacuum Booster WV 1200 A WV 1800 A WV 2400 A Instruction Manual 0870572562 A0006_en US Original instructions 5 18 2022...

Page 2: ...ion 11 5 3 Filling Oil 11 5 4 Fitting the Coupling 13 6 Electrical Connection 14 6 1 Machine delivered without Control Box or Variable Speed Drive VSD 14 6 2 Wiring Diagram Three Phase Motor 15 7 Comm...

Page 3: ...to state of the art methods Nevertheless residual risks may remain as described in the following chapters and in accordance with the chapter Intended Use 5 This instruction manual highlights potentia...

Page 4: ...C Barrier gas connection BPV Bypass valve EB Eye bolt IN Suction connection MP Magnetic plug MTB Motor terminal box NP Nameplate ODP Oil drain plug OFP Oil fill plug OSG Oil sight glass OUT1 Discharge...

Page 5: ...eeable misuse outside the intended use of the machine Risk of injuries Risk of damages to the machine Risk of damages to the environment Make sure to follow all instructions described in this manual T...

Page 6: ...k if the process gases are compatible with those following materials Cast iron Steel Aluminium Fluoroelastomer FKM FPM In doubt please contact your Busch representative 2 3 Shaft Sealing Variants 2 3...

Page 7: ...tor Only lift the machine as shown NOTICE In case the machine is already filled with oil Tilting a machine that is already filled with oil can cause large quantities of oil to ingress into the cylinde...

Page 8: ...ll apertures with adhesive tape or reuse provided caps If the machine is to be stored for more than 3 months Wrap the machine in a corrosion inhibiting film Store the machine indoors dry dust free and...

Page 9: ...in any other way Make sure that the oil sight glass OSG remains easily visible Make sure that enough space remains for maintenance work Make sure that the machine is placed or mounted horizontally a...

Page 10: ...2 Suction Connection WARNING Unprotected suction connection Risk of severe injury Do not put hand or fingers in the suction connection NOTICE Ingress of foreign objects or liquids Risk of damage to t...

Page 11: ...ize s DN100 DIN 28404 for WV 1200 1800 A DN160 DIN 28404 for WV 2400 A Same connection size for lateral discharge OUT2 Depending on the specific configuration ordered other connection dimensions may a...

Page 12: ...When the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 0...

Page 13: ...X 24 18 WV 1800 A WV 2400 A ROTEX 38 24 In case of a machine delivery without motor Fit the second coupling hub on the motor shaft separately delivered Axially adjust the hub in such a way until value...

Page 14: ...not be affected by electric or electro magnetic disturbance from the mains if necessary seek advice from Busch Make sure that the EMC of the machine is compliant with the requirements of your supply...

Page 15: ...for the motor Busch recommends installing a D curve circuit breaker Connect the protective earth conductor Electrically connect the motor NOTICE Incorrect connection Risk of damage to the motor The wi...

Page 16: ...tage motor with 9 pins low voltage Star connection multi voltage motor with 9 pins high voltage Double star connection multi voltage motor with 12 pins low voltage 4 4 4 Star connection multi voltage...

Page 17: ...ning the machine must be filled with oil see Filling Oil 11 NOTICE Lubricating a dry running machine compression chamber Risk of damage to the machine Do not lubricate the compression chamber of the m...

Page 18: ...e oil chambers Do not perform flushing without using the barrier gas Beforehand a barrier gas must be connected according to the following illustration and recommendations 1 2 3 4 Description 1 Proces...

Page 19: ...00 A_EN_en 19 36 When the flushing is finished Close the gas supply Dry the machine of flushing fluid Do not operate the machine in normal operating conditions with the barrier gas opened It might aff...

Page 20: ...r to any action requiring touching the machine let the machine cool down first CAUTION Failing to properly maintain the machine Risk of injuries Risk of premature failure and loss of efficiency Mainte...

Page 21: ...sings both sides see Oil Change 22 Every 6 months Perform an oil inspection change it if the oil has changed its initial color see Oil Color Inspection 21 Every 5000 hours or after 1 year Change the o...

Page 22: ...nstruction Manual PANDA WV 1200 2400 A_EN_en 8 4 Oil Change NOTICE Use of an inappropriate oil Risk of premature failure Loss of efficiency Only use an oil type which has previously been approved and...

Page 23: ...ntenance 8 Instruction Manual PANDA WV 1200 2400 A_EN_en 23 36 For oil type and oil capacity see Technical Data 30 and Oil 33 Fill up until the oiler OR is at least two thirds full with lip seals only...

Page 24: ...When the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 0...

Page 25: ...ny dismantling of the machine that goes beyond anything that is described in this manual should be done by Busch authorized technicians In case of the machine having conveyed gas that was contaminated...

Page 26: ...let the machine cool down first Shut down the machine and lock against inadvertent start up Disconnect the power supply Vent the connected lines to atmospheric pressure Disconnect all connections If...

Page 27: ...isk of premature failure Loss of efficiency The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty There...

Page 28: ...foreign matter or repair the machine contact Busch Equip the machine with a mesh screen at the suction connection The motor is defective Replace the motor The machine does not reach the usual pressure...

Page 29: ...ses at the inlet too high Observe the permitted gas inlet temperature see Technical Data 30 Oil level too low Top up oil The backing pump is not correctly defined Contact Busch The oil is black Oil ch...

Page 30: ...00 3000 3600 3000 3600 Sound pressure level 50Hz 60Hz dB A 59 63 60 64 67 71 Uncertainty KpA dB 3 Ambient temperature range C 5 40 Max gas inlet temperature C 200 P 10 hPa staging ratio of 4 Relative...

Page 31: ...uest On request On request On request On request 3 h max at delta P max in continuous operation Delta P max in 50 duty 20 min at delta P max 20 min at ultimate vacuum WV 1800 A 50 Hz 60 Hz Blower nomi...

Page 32: ...ration hPa 53 On request On request 53 On request On request Delta P max in 50 duty hPa 53 53 On request 53 53 On request Volume max every 2 minutes Standard bypass l No restric tion 1000 On request N...

Page 33: ...400 A_EN_en 33 36 15 Oil VSC 100 VSL 100 ISO VG 100 100 Part number 1 L packaging 0831 168 356 0831 122 573 Part number 5 L packaging 0831 168 357 0831 122 572 To know which oil has been filled in the...

Page 34: ...s substances in electrical and electronic equipment incl all related applicable amendments and comply ies with the following designated standards that have been used to fulfill those provisions Standa...

Page 35: ...tion of the use of certain hazardous substances in Electrical and Electronic Equipment Regulations 2021 and comply ies with the following designated standards that have been used to fulfill those prov...

Page 36: ...sence In every country highly competent local personnel delivers custom tailored support backed by a global network of expertise Wherever you are Whatever your business We are there for you Local repr...