7 | Maintenance
20 / 28
Instruction Manual MINK MM 1402-1502 AV_EN_en
NOTICE
Pressurised air systems supply too high pressure.
Risk of damage to the machine!
• Adjust the pressurised air to 0.2 bar(g) by means of a pressure regulator.
In case of clogged pressure relief lines:
• Remove the clogging or have the machine repaired (contact Busch).
Connect pressurised air to
the pressure relief lines
Unscrew plugs
Screw plugs
Remove the upper cover
Remount the upper cover
max. 0.2 bar (overpressure)
Tighten nuts
Remount pipes
Summary of Contents for MINK MM 1402 AV