8.3.4
Stage Testing
Motor start test:
100% of stages are tested at the manufacturing company and performances are stored for traceabil-
ity. This test intends to guarantee that the complete blower starts properly.
●
Use a stabilized 500 Watts power supply.
●
Plug the ground (black wire) on the motor housing. Plug the power (red wire) to the srcrew.
●
Set the voltage to 24V and the current to maximum (the compressor will consume what it
needs).
●
Shut down the power after 10 seconds.
8.3.5
Machine Identification
Relabelling the pump with the new label contained in the kit package:
●
Make sure that the serial number engraved on the gearbox cover of the machine is the same
than the one on the new label (make sure the traceability was not lost).
●
If the serial number is the same both on label and gearbox cover, stick the label on the motor
side. If not, check pairing.