7 | Maintenance
14 / 24
Instruction Manual R5 KD 0012-0020 A_EN_en
7.1 Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The
intervals given below are considered as starting values which should be shortened or ex-
tended as appropriate. Particularly harsh applications or heavy duty operation, such as
high dust loads in the environment or in the process gas, other contamination or ingress
of process material, can make it necessary to shorten the maintenance intervals signifi-
cantly.
Interval
Maintenance Work
Daily
.
• Top up the oil, if oil level underneath MIN-marking of
the oil sight glass (OSG).
• Drain the oil, if oil level exceeds MAX-marking of the
oil sight glass (OSG).
• Check the colour of the oil.
• Change the oil, if the oil shows a milky discoloration.
Weekly
.
• Check the machine for oil leaks - in case of leaks have
the machine repaired (contact Busch).
Every 2000 hours, or at least
every 6 months
• Change the oil and the exhaust filters (EF).
Every 5 years
• Have a major overhaul on the machine (contact
Busch).
7.2 Oil Level Inspection
• Shut down the machine.
• When the machine is stopped, wait 1 minute before checking the oil level.
MAX
MIN
MAX
MIN
MAX
MIN
• Fill up if necessary, see