2.7.2 P&ID "Piping and Instrumentation Diagram"
TSA+
0102
MV4
0201
LS-
0202
LS-
SA+
0701
TSA+
0103
PSA+
0301
MV3
MV2
MV5
FS-
0501
FME
FME
FME
FS-
0503
FS-
0504
FLV
NRV
NRV
NRV
GC
NIF
MAN
PS+
0301
IN
OUT
TSA+
0101
FA
FA
D
C
FS+
0501
FME
NRV
D
C
E
E
PS-
0302
M
CPL
MOT
DN50 PN16
CWO
CWI
MV7
CWP
TV
WIF
NRV
A
B
FL
CWO
CWI
MV7
PHE
CLP
TTV
55°C
A
B
G1/2
G1/2
G1/4
GS
0601
GS
0602
MV6
PMC
PRV
MAN
PRV
MAN
PRV
MAN
PRV
G1/4
Barrier gas system
Purge gas system
Dilution gas system
With gas lubricated double mechanical seals
Flame arrester
bypass
= optional
= variant
Flushing liquid device
With plate heat exchanger
With direct cooling
or
DN15
PN10
DN40 PN16
(NC0100B)
DN50 PN16
(NC0200-0300B)
DN15
PN10
DN50 PN16
DN40 PN16
(NC0100B)
DN50 PN16
(NC0200-0300B)
MV5
GC
G1/4
For dilution gas system only
or
= optional
Barrier gas system
Purge gas system
Dilution gas system
Flushing liquid device
= variant
With gas lubricated double mechanical seals
P&ID for classification A and B
Flame arrester
bypass
(see ATEX classification, chapter 2.7.1)
For dilution gas system only
CPL
Coupling
CWI
Cooling water inlet
CWO
Cooling water outlet
CLP, CWP
Cooling liquid/water pump
FA
Flame arrester
FL
Flow limiter
FLV
Flushing liquid vessel
FME
Flow meter
FS
Flow switch
GC
Gas connection
GS
Limit switch
IN
Suction connection
LS
Level switch
MAN
Manometer
MOT
Motor
MV
Solenoid valve
NIF
Nitrogen inlet filter
NRV
Non-return valve
OUT
Discharge connection
PHE
Plate heat exchanger
PMC
Pneumatic connection
PRV
Pressure regulating valve
PSA
Pressure transmitter
PS
Pressure switch
SA
Vibration transmitter
TSA
Resistance thermometer
TTV
Three-way thermostatic valve
TV
Thermostatic valve
WIF
Water inlet filter
Summary of Contents for COBRA ATEX NC 0100-0300 B