TECHNICAL DATA
Gas; supply pressure Butane/propane 30 mbar
Butane/propane 37 mbar
Product category
I3B/P(30)
I3B/P(37)
Injector size
Outer ring: 1.3 mm
Inner ring: 1.0 mm
Tot. nom. heat output
I3B/P(30):12.0 kW / 872.6 g/h
I3B/P(37):12.5 kW / 909.0 g/h
Lighting
Integrated
Gas cylinder
Max height
590 mm
Max diameter
310 mm
Max content
10 kg
DESCRIPTION
1. Rim
2. Burner
3. Leg
4. Grille shelf
5. Screw M6x35
6. Nut M6
7. Screw M6x20
FIG. 1
FIG. 2
ASSEMBLY
See diagrams for correct assembly of the
product.
FIG. 3
FIG. 4
FIG. 5
CONNECTING THE GAS CYLINDER
WARNING!
• Before connecting the gas cylinder,
check that the coupling, regulator,
burner and burner parts are in good
condition.
• If the hose is replaced it must be secured
on the grill and the regulator
connections with hose clips. Disconnect
the regulator from the gas cylinder
when the gas grill is not in use.
• Follow the instructions supplied with the
regulator.
CONNECTING THE GAS CYLINDER
NOTE:
Gas cylinder and regulator sold separately.
• Place the product on a level, stable
surface. Check that the inlet and outlet
regulator suit the gas cylinder valve and
the product.
• If the regulators are kept outdoors, protect
them from precipitation, etc.
• A spanner is needed to connect the gas
cylinder.
• Check that the hose is not clinched or
twisted when connecting.
• Place the gas cylinder on the left side of
the product, in a safe place protected
from heat.
• The hose diameter must be 8–10 mm.
The hose must not be longer than 1.5 m.
1. Gas connection
2. Hose
3. Gas cylinder
4. Gas regulator
5. Hose
FIG. 6
LEAKAGE TEST
1. Mix 1 part of washing-up liquid/soap with
Summary of Contents for 012682