2  Technical Information 

 

2.1

 

Technical Data 

 

INVERTERJET MODEL 

30M/L  

30M/N 

50M/L 

50M/N 

90M/L 

90M/N 

Type 

 

Pre-Mix Burner 

Pre-Mix Burner 

Pre-Mix Burner 

Fuel Type 

 

LPG 

NG 

LPG 

NG 

LPG 

NG 

Power 

Min 

kW 

10 

18 

Max 

kW 

30 

50 

90 

Modulation Range 

 

1:5 

1:5 

1:5 

Nominal Voltage 

VAC 

230 

230 

230 

Frequency 

Hz 

50/60 

50/60 

50/60 

Phase 

 

1 ~ 

1 ~ 

1 ~ 

Fan Current Draw 

Max 

0.3 

1.9 

1.9 

Gas Connection Flange Size 

 

1/2 “BSP                                  

1/2 “BSP                                  

1/2 “BSP                                  

Gas Inlet Pressure 

Min 

mbar 

10 

10 

10 

Max  mbar 

60 

60 

60 

 

                                 

2.2

 

Technical Description of the Burner Parts 

 
The Burners in the Inverterjet M series have the following technical description of 
the parts. 
 

 

 

 

 

 
 

Burner Mounting Plate 

Ignition Electrode 

Ionisation Probe 

Gas Connection Flange 

Pressure Feedback Connector 

Offset Adjustment Screw 

Reset Button 

Indicator Light (Alarm) 

Burner Controller 

10  Throttle Adjustment Screw 
11  Fan Housing 
12  Burner Head Earth Connector 
13  Burner Head 
14  Gas Valve 
15  Venturi 

 

 
 

Summary of Contents for INVERTERJET 30M/L

Page 1: ...bject to Modifications MODEL PRODUCT CODE CLASS INVERTERJET 30M L 91353 MODULATING PRE MIX BURNER INVERTERJET 30M N 91354 MODULATING PRE MIX BURNER INVERTERJET 50M L 91320 MODULATING PRE MIX BURNER IN...

Page 2: ...4 Commissioning 12 4 1 Commissioning procedure 12 4 1 1 Turning on the Burner 13 4 1 2 Commissioning operation 13 4 1 2 1 Maximum rate CO2 13 4 1 2 2 Minimum rate CO2 13 4 1 2 3 Burner Heat Input 13 4...

Page 3: ...ility we advise and request that a Burnertech Approved Engineer who has attended our product course conducts the 1st burner commissioning For Training Service or Commissioning information please conta...

Page 4: ...Installation Service User Manual BURNERTECH 3...

Page 5: ...Max A 0 3 1 9 1 9 Gas Connection Flange Size 1 2 BSP 1 2 BSP 1 2 BSP Gas Inlet Pressure Min mbar 10 10 10 Max mbar 60 60 60 2 2 Technical Description of the Burner Parts The Burners in the Inverterje...

Page 6: ...ght mm mm mm mm mm mm mm mm mm kg Inverterjet 30M L 89 71 91 101 6 170 133 218 361 225 5 2 Inverterjet 30M N 89 71 91 101 6 170 133 218 361 225 5 2 Inverterjet 50M L 92 71 91 101 6 170 164 244 365 238...

Page 7: ...d ten volts can be applied to connector X3 Pins 8 16 At zero volt the fan will run on Minimum Fan speed At ten volt the fan will run on Maximum Fan speed 4 20 mA control with an external resistor of 5...

Page 8: ...Installation Service User Manual BURNERTECH 7 3 Installation 3 1 General Installation Information...

Page 9: ...sealing and insulating between the Mounting Plate and the bearing wall of the appliance 3 2 1 Standard Burner Mounting Detail 1 Burner Head 2 Burner Mounting Gasket 3 Boiler Door MODEL C D1 D2 G PCD...

Page 10: ...front of the Gas connection flange at the rear of the burner 2 Check the thread on the flange and ensure that there is no debris in the threads 3 Connect the corresponding gas pipe fittings to the Gas...

Page 11: ...Installation Service User Manual BURNERTECH 10 3 4 Electrical Installation The electrical wiring diagram for the Burners are shown in the following page 3 5 Basic Electrical Safety...

Page 12: ...fit connector is used for communication via a dedicated Windows based PC software and USB lead Please contact Burnertech for more information An Earth must be connected to the 6 3mm spade connector on...

Page 13: ...g procedure follow the steps bellow 1 Connect a Manometer to the gas inlet pressure test nipple on the burner gas inlet connection 2 Locate CO CO2 combustion analyser into flue pipe as close as possib...

Page 14: ...5 CAUTION Generally the CO2 should not normally exceed 9 5 on NG or 11 on LPG We recommend that the operating CO2 is between 0 to 0 5 higher at maximum fan speed than at minimum 4 1 2 2 Minimum rate...

Page 15: ...during a complete burner sequence The basic states are Stand by fan is off or at Continuous Fan speed when this option is selected Pre purge Ignition Run state fan speed is controlled by modulation i...

Page 16: ...mmunication 4 1 3 1 PC USB Interface If required a windows based software along with a dedicated USB cable and driver is available to enable programming of certain parameters in the control and also t...

Page 17: ...Installation Service User Manual BURNERTECH 16 5 User Instructions 5 1 Limitations on use of Burner...

Page 18: ...uous Fan speed option is switched off 5 2 3 Heating Mode The normal heating mode is started when a high voltage heat demand input is closed When ignition is successful the fan can be controlled betwee...

Page 19: ...m the chamber 6 1 1 The condition of the burner head some discolouration of the burner material is normal but the material should not be cracked or open Under no circumstances should any of the perfor...

Page 20: ...ion The fan case has gas tight seals and the fan casing must never be opened Due to the 1 1 gas air ratio operating principle of the burner a reduction in fan performance i e dust build up will not re...

Page 21: ...alse Flame Indication Error is created if flame current is detected in illegal situations no heat demand currently present gas valve closed safety time passed This error condition requires manual rese...

Page 22: ...Installation Service User Manual BURNERTECH 21 6 3 2 Maintenance Notes...

Page 23: ...Installation Service User Manual BURNERTECH 22...

Page 24: ...C Lostock Industrial Estate Lostock Lane BL6 4BL Bolton United Kingdom Tel 44 0 1204 393222 Fax 44 0 1204 394222 Email enquiries burnertech co uk Website www burnertech co uk 99043 1 28 11 2019 Subje...

Reviews: