FOR YOUR SAFETY - If you smell gas

:

 

Shut off all gas supplies.

 

Extinguish all open flames.

 

Contact a qualified gas service technician for assistance.

 

 

This torch will produce extremely hot flames, and will cause severe 

burns to exposed skin. 

 

You must always use hand and eye protection when using this torch. It 

is recommended that you use OSHA approved eye protection and 
leather gloves whenever using this torch. 

 

DO NOT use this torch in any area containing flammable vapors such as 

gasoline, paint thinner, or degreaser. 

 

DO NOT use this torch near flammable material such as dead & dry 

weeds, pine needles, sawdust, & paper. 

This torch is only intended for outdoor use only.

 

This torch is designed for use with a vapor withdrawal LPG (propane type 

CGA

-

510) cylinder only.

 

Only allow properly trained adults to operate this torch.

 

Do not allow children to operate this torch.

 

 

 

SET-UP INSTRUCTIONS 

Before you begin … 

Inspect all material for damage.

 

Make sure all brass connectors are free from breaks or damage.

 

Make sure torch assembly is not bent or broken.

 

DO NOT USE THIS TORCH IF ANY PART IS DAMAGED OR BROKEN

 

You must provide a UL listed LP Gas Hose with 9/16”

-

18 LH connections, an adjustable 

LP Gas (Propane) regulator – for tank pressure inlet service up to, but no more than 30 PSI 
outlet pressure rating, and a LPG vapor withdrawal propane supply cylinder. This cylinder 
must be approved by the US Department of Transportation for propane service.

 

Inspect the O

-

ring (if applicable) on the CGA

-

510 cylinder connector fitting, on the LPG 

(propane) pressure regulator, for damage. If damaged, do not use the torch. Replace the O

-

ring.

 

Connect the CGA

-

510 cylinder connector fitting to the LPG withdrawal propane supply 

cylinder. (Refer to illustration)

 

 

DO NOT OVER TIGHTEN 

Make sure the torch control valve is turned completely OFF (fully clockwise). 

SLOWLY 

open the gas valve on the propane supply cylinder. Immediately check for any gas leaks on 
the torch control valve, the gas hose, and the CGA

-

510 tank connector fitting using a soapy 

water or suitable gas leak detection solution (available at your local LP Gas Retailer).  

 

DO NOT USE A MATCH OR ANY OTHER OPEN FLAME TO DETECT 
FOR GAS LEAKS. 

DO NOT OPERATE OR ATTEMPT TO LIGHT OR OPERATE THIS 
TORCH IF THERE IS ANY EVIDENCE OF A GAS LEAK OR YOU 
SMELL GAS. 

If a leak is discovered, immediately turn OFF the gas valve on the propane cylinder.

 

LIGHTING INSTRUCTIONS 

Before you begin … 

Make sure you have followed the SET

-

UP INSTRUCTIONS completely. 

 

SLOWLY 

open the gas valve on the propane supply cylinder. Check all connections on the 

torch, hose and cylinder for leaks, using a soapy water solution or a suitable gas leak detec-
tion solution (available from your local LP Gas supplier). Watch all connections carefully. If 
bubbles appear, a leak is present in that area. Shut OFF the gas supply valve on the propane 
cylinder

.

 

DO NOT OPERATE OR ATTEMPT TO LIGHT OR OPERATE THIS 
TORCH IF A LEAK IS PRESENT. 

Open the gas control valve on the torch 1/8 of a turn, or until a small amount of gas begins to 
escape from the torch. Using the flint striker supplied with your torch kit, ignite the gas at 
the burner head end of the torch.

 

NEVER USE A MATCH OR CIGARETTE LIGHTER TO IGNITE THE GAS 
– THIS CAN LEAD TO SERIOUS BURNS AND INJURIES 

DO NOT ATTEMPT TO IGNITE THE GAS FOR MORE THAN FIVE (5) 
SECONDS

.

 

If you cannot light the torch within 5 seconds, turn OFF both the gas control valve on the 
torch and the gas supply valve on the propane cylinder. Adjust the size of the flame by using 
the adjusting knob on the LP (propane) pressure regulator or gas control valve on the torch

.

 

IMPORTANT PERFORMANCE NOTE 

The CGA

-

510 cylinder connector may be equipped with a safety device known as an 

Excess

-Flow Safety Check

. This safety device prevents large amounts of propane from escaping if 

there is a hose failure. 

This safety device may activate when you first turn ON the pro-

pane gas supply. 

To correct this problem, simply

 close the propane gas supply valve 

on 

the propane cylinder, wait 15 seconds, and then very slowly open the propane supply valve. 
This should return the torch system to a normal performance level.

 

If your torch is still not performing at a normal level, have your local propane supplier verify 
that your propane supply cylinder is operating correctly.

 

SHUT-OFF INSTRUCTIONS 

Turn OFF the valve on the gas supply cylinder first. Allow all of the gas to burn completely 
and the flame to extinguish at the burner head. Turn OFF the gas control valve on the torch.

 