INSTRUCTIONS FOR THERMOWELD GROUNDING CONNECTIONS - ABR-1 TYPE MOLDS

ABR-1

Place receptacle and ground rod into the mold.  The ground rod 

should be touching the receptacle.  Besure ground receptacle is 

seated and that the ground rod is not holding it up from the mold.  

Next insert bus bar until it butts against the side of the ground 

rod.  Use a pair of locking pliers or a clamp to prevent mold from 

slipping when fired.