1.0  IMPORTANT RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage. Shipping 
damage is not covered by warranty. If shipping damage is found, 
notify carrier at once. The carrier is responsible for all repair and 
replacement costs resulting from damage in shipment.

SAFETY FIRST

2.0  GENERAL HYDRAULIC SAFETY PRECAUTIONS

Read all instructions, warnings and cautions 
carefully. Follow all safety precautions to avoid 
personal injury or property damage during system 

operation. Enerpac cannot be responsible for damage or injury 
resulting from unsafe product use, lack of maintenance or 
incorrect product and/or system operation. Contact Enerpac 
when in doubt as to the safety precautions and operations. If 
you have never been trained on high-pressure hydraulic safety, 
consult your distribution or service center for a free Enerpac 
Hydraulic safety course.

Failure to comply with the following cautions and warnings 
could cause equipment damage and personal injury.

CAUTION

 is used to indicate correct operating or 

maintenance procedures and practices to prevent damage to, 
or destruction of equipment or other property.

WARNING

 indicates a potential danger that requires correct 

procedures or practices to avoid personal injury.

DANGER

 is only used when your action or lack of action 

may cause serious injury or even death.

WARNING:

 Wear proper personal protective gear 

when operating hydraulic equipment.

WARNING:

 Do not exceed equipment ratings. 

Overloading causes equipment failure and possible 
personal injury. The nut splitter is designed for a 

maximum pressure of 700 bar [10,000 psi]. Do not connect the 
nut splitter to a pump with a higher pressure rating.

Never

 set the relief valve to a higher pressure than the 

maximum rated pressure of the pump. Higher settings 
may result in equipment damage and/or personal 
injury.

WARNING:

 The system operating pressure must not 

exceed the pressure rating of the lowest rated 
component in the system. Install pressure gauges in 

the system to monitor operating pressure. It is your window to 
what is happening in the system.

CAUTION: 

Avoid damaging hydraulic hose. Avoid 

sharp bends and kinks when routing hydraulic hoses. 

Using a bent or kinked hose will cause severe back-pressure. 
Sharp bends and kinks will internally damage the hose leading 
to premature hose failure.

Do not

 drop heavy objects on hose. A sharp 

impact may cause internal damage to hose wire 
strands. Applying pressure to a damaged hose 

may cause it to rupture.

IMPORTANT:

 Do not lift hydraulic equipment by the 

hoses or swivel couplers. Use the carrying handle or 
other means of safe transport.

CAUTION:

 Keep hydraulic equipment away from 

fl 

ames and heat. Excessive heat will soften 

packings and seals, resulting in fl uid leaks. Heat 

also weakens hose materials and packings. For optimum 
performance do not expose equipment to temperatures of 
65°C [150°F] or higher. Protect hoses and cylinders from weld 
spatter.

DANGER:

 Do not handle pressurized hoses. 

Escaping oil under pressure can penetrate the skin, 
causing serious injury. If oil is injected under the skin, 

see a doctor immediately.

IMPORTANT:

 Hydraulic equipment must only be 

serviced by a qualifi ed hydraulic technician. For repair 
service, contact the Authorized ENERPAC Service 

Center in your area. To protect your warranty, use only ENERPAC 
oil.

WARNING:

 Immediately replace worn or damaged 

parts with genuine ENERPAC parts. Standard grade 
parts will break causing personal injury and property 

damage. ENERPAC parts are designed to fi t properly and 
withstand high loads.

Index:

 English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-7
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A 
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A 
Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A 
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A 
Nederlands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Portuguese  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Finnish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Norwegian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Swedish. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A

中文

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A

日本語

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A

L2923 Rev. 

B 09/09 

Summary of Contents for NS Series

Page 1: ...he nut splitter to a pump with a higher pressure rating Never set the relief valve to a higher pressure than the maximum rated pressure of the pump Higher settings may result in equipment damage and or personal injury WARNING The system operating pressure must not exceed the pressure rating of the lowest rated component in the system Install pressure gauges in the system to monitor operating press...

Page 2: ...inder to fully retract before disconnecting hydraulic hose s High pressure fluid may be ejected from an unretracted cylinder if a coupler has been damaged during handling Fully release hydraulic pressure and disconnect hydraulic hose s from nut splitter cylinder before applying lubricant to blade or performing any other work inside the cutting zone Be careful when handling severed nuts Sharp edges...

Page 3: ...7 7 196 16 6 422 82 7 37 5 23 0 377 0 NSC 70 NSC 70D NSH 7085 NSB 70 NS 7095 NS 7095D 103 2 918 6 3 160 1 3 32 7 1 180 0 3 8 0 3 2 81 7 9 201 17 432 84 9 38 5 23 0 377 0 NSC 70 NSC 70D NSH 7095 NSB 70 NS 70105 NS 70105D 103 2 918 6 9 174 1 4 35 7 1 180 0 4 9 0 3 2 81 8 2 209 17 5 443 87 1 39 5 23 0 377 0 NSC 70 NSC 70D NSH 70105 NSB 70 NS 110115 NS 110115D 192 5 1712 7 4 189 1 4 36 9 2 234 0 1 3 7...

Page 4: ...psi 700 bar operation See Figure 4 for typical pump and hose arrangements Single acting nut splitters are equipped with one Enerpac CR 400 3 8 female coupler Double acting nut splitters are equipped with two Enerpac CR 400 3 8 female couplers Figure 4 Hydraulic Connections typical pumps shown Connect the hydraulic hose s between the pump and the nut splitter cylinder Check that couplers on both en...

Page 5: ... damage to the bolt threads Refer to sections 6 1 and 6 2 for adjustment instructions 4 Connect hydraulic hose s as described in Section 5 3 Check that hydraulic pump reservoir is filled to the correct level 5 To help prolong blade life lubricate the blade cutting edge and flanks with a molybdenum disulphide based lubricant or other high quality lubricant CAUTION Wear gloves when applying lubrican...

Page 6: ...positioned back in the same nut groove 4 If step 3 did not work Re lubricate the blade and the nut groove again Lift and position the nut splitter above the flange surface so that the blade will penetrate the nut approximately the height of the nut and in the same groove Then re apply pressure 5 If step 4 did not work Install a larger cutting head if available or use a larger nut splitter model Be...

Page 7: ...lds pressure but piston and blade do not move or move only a partial amount Pump reservoir not vented If using a vented pump loosen vent fill cap or vent screw as required to provide venting Coupler not fully assembled Check couplers Both hoses not connected double acting models only Be sure that both hoses are connected Piston at full stroke Allow piston to retract Blocked hose Replace hose 3 Nut...