Note: For other gases contact the manufacturer.
Models: Tiki Cone – Anodized aluminium copper
Tiki Cone – Anodized aluminium black
These instructions shall be left with the appliance for the consumer to retain for future reference.
NOTE:
To convert L.P. Tiki Torches to Natural Gas use, change orifice #54 to #48. Install 2 of the 3/16” machine plugs in
the primary air intake openings, which will render all openings for primary air Closed..
INSTALLATION NOTES
1.
When installing the Tiki Torch heads on an angle, make sure the drainage holes in the bottom of the cone are at
the most bottom position of the cone.
2.
Torch heads should be mounted no less than 6’ from ground level. More in public areas if there is a chance for
any public to come in contact with the flame.
3.
If installed in a public area, it is recommended that a lockable gas valve be used.
4.
All pipe connections should be pressure or soap tested as described in
local codes.
MAINTENACE INSTRUCTIONS
1.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and
liquids.
2.
Visually check the burner for soot or blockage on a periodic basis, clean if required.
3.
The Burner and orifice should be serviced once a year or after long periods of none usage.
4.
This is done by removing the complete cone head from the piping, by putting a wrench on the hex nut #1 on the
piping and the hex nut #2 close to the base of the cone. Turn anti clock wise and the two hex nuts will separate
to expose the orifice jet in the remaining hex nut on the piping. Remove the orifice jet and inspect, clean with
proper orifice cleaner if required. (Often insects will nest in there over long period of non use.)
6/32 stainless steel screw