Note:  For other gases contact the manufacturer. 
 
Models:  Tiki Cone – Anodized aluminium copper 
 

    Tiki Cone – Anodized aluminium black 

 
These instructions shall be left with the appliance for the consumer to retain for future reference. 
 
 

NOTE:

  To convert L.P. Tiki Torches to Natural Gas use, change orifice #54 to #48. Install 2 of the 3/16” machine plugs in 

the primary air intake openings, which will render all openings for primary air Closed.. 
 

INSTALLATION NOTES

 

 

1. 

When installing the Tiki Torch heads on an angle, make sure the drainage holes in the bottom of the cone are at 
the most bottom position of the cone. 

 

 

 

 

 
 

2. 

Torch heads should be mounted no less than 6’ from ground level.  More in public areas if there is a chance for 
any public to come in contact with the flame. 

 

3. 

If installed in a public area, it is recommended that a lockable gas valve be used. 

 

4. 

All pipe connections should be pressure or soap tested as described in

 local codes. 

 

 

MAINTENACE INSTRUCTIONS 
 

1. 

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and 
liquids. 

 

2. 

Visually check the burner for soot or blockage on a periodic basis, clean if required. 

 

3. 

The Burner and orifice should be serviced once a year or after long periods of none usage. 

 

4. 

This is done by removing the complete cone head from the piping, by putting a wrench on the hex nut #1 on the 
piping and the hex nut #2 close to the base of the cone.  Turn anti clock wise and the two hex nuts will separate 
to expose the orifice jet in the remaining hex nut on the piping.  Remove the orifice jet and inspect, clean with 
proper orifice cleaner if required.  (Often insects will nest in there over long period of non use.) 

 

6/32 stainless steel screw 

 

 

3

Summary of Contents for TIKI TORCHES

Page 1: ...open flame 5 Immediately call your gas supplier NOTE The installation of these Tiki Torches must conform with local codes or in the absence of local codes with National Fuel Code ANSI 223 1 1 _____________________________________________________________________________ FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance ...

Page 2: ...y piping used should be securely fastened to the building or structure with adequate clamps and fasteners It is recommended that each individual head have a manual shut off valve installed up stream and be mounted so that in the closed position the handle is across the piping run These Tiki Torch Cones should not be installed closer than 3 from combustible materials or in accordance with local cod...

Page 3: ...ame 3 If installed in a public area it is recommended that a lockable gas valve be used 4 All pipe connections should be pressure or soap tested as described in local codes MAINTENACE INSTRUCTIONS 1 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 2 Visually check the burner for soot or blockage on a periodic basis clean if required ...

Page 4: ...quired Using 54 drill bit for LP and 48 drill bit for NG clean the burner orifices if required 6 Re assemble it is recommended to replace the 1 x 1 16 buna o ring between the hex nuts Call or use the manufactures web site for a dealer nearest to you 7 Fire unit and observe the flame The flame should be a lazy yellow flame with some blue at the base and no visible smoke 4 ...