Burlington T2DB Installation Instructions Download Page 4

4 - 5

B

1. Turn the water flow control handle to increase/decrease 
    the water flow and turn on/off.
2. Turn the temperature control handle to increase/decrease 
     the water temperature. 
3. The temperature control knob is pre-set the auto stop at 42°C to
    avoid scalding.
However, if for any reason the setting is removed it is important to
follow “Temperature Setting” procedure to reset.

Operation

HOT

COLD

TEMPERATURE 

CONTROL

WATER FLOW

CONTROL

DL

O

n

C

TH

AB

H S

OW

ER

TO

H

27

SHOWER

BATH

Temperature Setting

The temperature control handles on this product are factory set and should require no adjustment. 
However, if for any reason the handles and/or the cartridge is removed it is important the following procedure is followed. 

1 ) Remove the temperature control handle, metal block (see Fig 1).
2 ) Rotate the exposed thermostatic spindle (clockwise for cold, and anti-clockwise for hot), until the maximum desired showering temperature is set. 
     The suggested maximum “pre-set” temperature is 42°C (see Fig 2). 
3 ) Without any move at the spindle, replace the metal block so that limit stop up to the right hand side of the limit stop on the cartridge (see Fig 3).
4 ) Then refit the temperature control handle. 

METAL BLOCK

SPINDLE

LIMIT STOP

1

2

3

4

Maintenance (Thermostatic Cartridge)

* After a long time usage of thermostatic valve, there will be some waste debris from the water pipe on and around the check valve or 
  thermostatic cartridge, which will affect the flow and sensitivity of automatical temperature adjustment. Please take out the thermostatic 
  cartridge, and clean the cartridge strainer.
* To avoid damage, please remove all chrome parts before any maintenance takes place. 

Maintenance (Filter & Check valve)

A) Cutoff the Hot & Cold supply at the isolating valve. 
     Disconnect the hot & cold water supply from the valve.
B) Take down the valve from the feet.
C) Take out the filter, check valve.
D) Clean the filter and check valve with clean running water, 
     dry and lightly grease the seals. (only use silicone grease)
E) Put back all of the parts in sequence.

FILTER

CHECK VALVE FIXING NUT

“ O” RING

Summary of Contents for T2DB

Page 1: ... than 25 The British Burns Association recommends 37 to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act 2000 the maximum mixed water outlet temperature of 43 C Important We recommend that this product is installed by a qualified professional contractor Such as a plumber who is certified by NVQ National Vocational Qualification or SNVQ Scottish...

Page 2: ... mixer on the bath you need to install the deck mounting unions on the bath first a Remove the washers and fixing nuts from the tails of deck mounting unions b Insert the tails through two tap holes on bath which should be at 180mm centers c Tighten the rubber washer the fixing nut from the under side of the bath d Tighten the bath shower mixer on joint nut and connect to the deck mounting unions ...

Page 3: ...lied washer if you feel the water flow from handset is too low PCW WATER REGULATOR The water flow hits the black O ring first O ring B FLOW STRAIGHTENER The tap comes with a factory fitted flow straightener for low pressure water systems If the water flow is high replace the factory fitted flow straightener with the high pressure aerator supplied Use NEOPERL Key to unscrew the straightener in the ...

Page 4: ...s set The suggested maximum pre set temperature is 42 C see Fig 2 3 Without any move at the spindle replace the metal block so that limit stop up to the right hand side of the limit stop on the cartridge see Fig 3 4 Then refit the temperature control handle METAL BLOCK SPINDLE LIMIT STOP 1 2 3 4 Maintenance Thermostatic Cartridge After a long time usage of thermostatic valve there will be some was...

Page 5: ...perature 3 Allow water running 5 seconds for stability measure the mixed water temperature at the outlet The mixed water temperature at the outlet should never exceed 42 C for showers The mixed water temperature at the outlet should never exceed 46 C for bath filler Note 46 C is the maximum mixed water temperature from the bath tap The maximum temperature takes account of the allowable temperature...

Reviews: