BURL B80-BMB3 MOTHERSHIP Quick Start Manual Download Page 1

B80-BMB3 

MOTHERSHIP

BMB3 Rev C Rom 1

Quick Start Guide

Section 1: Getting Started

Section  2: Dante Quick Start

Section  3: Dante Clocking

Revision 1.6 March 29, 2018

Summary of Contents for B80-BMB3 MOTHERSHIP

Page 1: ...B80 BMB3 MOTHERSHIP BMB3 Rev C Rom 1 Quick Start Guide Section 1 Getting Started Section 2 Dante Quick Start Section 3 Dante Clocking Revision 1 6 March 29 2018...

Page 2: ...e BMB3 Motherboard as shown in Image 1 below 2 Use Examples A through D on pages 2 and 3 to determine which setting to use based on your configuration 3 See Channel Mapping for Jumper Settings charts...

Page 3: ...4 are found in slot 1 outputs 1 8 are found in slot 7 EXAMPLE A JUMPERS ON 1 AND 3 FACTORY SETTING BMB3 jumper settings for a 40 in x 40 out system using BAD8 and BDA8 Daughter Cards EXAMPLE B NO JUMP...

Page 4: ...for a 32 in x 32 out system using BAD8 BDA8 BAES4 and BCLK Daughter Cards EXAMPLE D JUMPERS ON 1 AND 4 BMB3 jumper settings for a 16 in X 64 out system using BAD8 and BDA8 Daughter Cards Image 7 Jumpe...

Page 5: ...To purchase blanks for empty MOTHERSHIP slots contact your BURL dealer For more information on installing Daughter Cards please go to www burlaudio com b80 quick start video 1 3 Install Daughter Cards...

Page 6: ...P MUST run with proper ventilation Failure to properly vent the MOTHERSHIP chassis above and below may cause failure and will void the warranty CONTINUE TO SECTION 2 DANTE QUICK START page 6 SECTION 3...

Page 7: ...DVS may be used in place of a PCIe Card DVS will add 4ms of latency in and out for a total round trip of 8ms Total latency of the system will include the latency of the converter chips and the DAW We...

Page 8: ...ller requires a native Ethernet port and will not work via the PCIe Card 2 7 If Using A PCIe Card Connect Primary Port Of PCIe Card To Gigabit Ethernet Switch When using a Dante PCIe Card audio is tra...

Page 9: ...herboard and then to the PCIe Card or CPU when using DVS Receiver refers to the PCIe Card sending signal to the BKII Card on the BMB3 Motherboard which then feeds the MOTHERSHIP output card Image 10 S...

Page 10: ...ut assignments for your MOTHERSHIP configuration See Image 16 pg 11 2 14 Output Assignment Route BMB3 Receiver channel 1 to PCIe or CPU if using DVS Transmitter channel 1 This routes PCIe ch 1 to B80...

Page 11: ...configuration See Image 14 for an example of routing B80 MOTHERSHIP outputs to the PCIe Card 2 15 Click On Device Info Then double click on BMB3 to open Device View window See Image 15 Image 14 Shows...

Page 12: ...ill have a 4ms latency in and out Using a PCIe Card is recommended to get down to 150 s 2 17 Click On The Dropdown Menu Select DEVICE CONFIG for each Dante device including the PCIe Card Make sure the...

Page 13: ...I Card set to Internal 3 1 Clocking BMB3 To Internal Word Clock 1 Set BMB3 front panel to INT 2 Open Dante Controller select DEVICE INFO 3 Double Click on device BMB3 xxxxxx 4 Click on CLOCK STATUS Im...

Page 14: ...BMB3 front panel to EXT 2 Open Dante Controller select DEVICE INFO 3 Double Click on device BMB3 xxxxxx 4 Click on CLOCK STATUS Image 18 5 Set BMB3 to Preferred Master and Enable to sync to External...

Page 15: ...n device BMB3 xxxxxx 4 Click on CLOCK STATUS Image 19 5 Set BMB3 to Preferred Master and deselect Enable to sync to External 6 Make sure each device including host PCIe Card is set to correct sample r...