background image

S070

p. 1/4

www.burkert.com

Positive displacement sensor fitting 
for continuous flow measurement

This positive displacement sensor fitting is specially designed for flow measurement and/or batch control of highly viscous fluids like glue, honey or oil.

This measuring element must be associated to an electronic module SE30, SE32, SE35, SE36 with hall sensor principle only, quickly 
and easily connected together by a Quarter-Turn.
The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of 
measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design. 
The low pressure drop and high pressure rating make it suitable for both gravity and pump 

(in-line)

 applications.

Type 8070

Positive displacement 
flowmeter

Type 8072

Positive displacement 
flowmeter

Type 8075

Positive displacement 
flowmeter

Type S070 can be combined for...

•  DN15 to DN100

•  INLINE Quarter-Turn technology

•  Electronics available for indication, monitoring, trans-

mitting, On/Off control and batch control

General data

Compatibility

With electronic SE30, SE32, SE35, SE36 
with Hall sensor principle 

(see separate data sheet)

Wetted parts ma-
terials

   Body

Rotor
Shaft
Seal

Aluminium, stainless steel 

(316F)

PPS, aluminium, stainless steel 

(316F)

Stainless steel 

(316F)

FKM or FEP/PTFE encapsulated

Environment

Ambient temperature

0 to 60°C 

(32 to 140°F)

 

(operation and storage)

Standards, directives and approvals

Protection class

IP66 

(NEMA 6)

Directives

 Pressure

Complying with article 3 of §3 from 
97/23/CE directive*. 

(without CE mark)

* For the 97/23/CE pressure directive, the device can only be used under following condi-
tions (dependent on max. pressure, pipe diameter and fluid).

Type of fluid

Conditions

Fluid group 1, §1.3.a

Forbidden

Fluid group 2, §1.3.a

DN 



32, or DN > 32 and PN*DN 



1000

Fluid group 1, §1.3.b

PN*DN 



2000

Fluid group 2, §1.3.b

DN 



200

Type 8076

Positive displacement 
flowmeter

Complete device data

Pipe diameter

   Thread connection

Flange connection

DN15 to DN100
½”; 1”; 1½”; 2”; 3” 

(G or NPT)

25; 40; 50; 80 or 100 mm DIN PN16 flange
1”; 1½; 2”; 3” or 4” ANSI 150LB flange

Measuring range

   Viscosity > 5 cps

Viscosity < 5 cps

2 to 1200 l/min 

(0.53 to 320 gpm)

3 to 616 l/min 

(0.78 to 160 gpm)

Medium tempera-
ture max.

Aluminium body: 80°C 

(176°F)

Stainless steel body: 120°C 

(248°F)

Medium pressure 
max.

   DN15

DN25
DN40/DN50
DN80
DN100

55 bar 

(798.05 PSI) 

(threaded process connection)

55 bar 

(798.05 PSI) 

1)

18 bar 

(261.18 PSI)

12 bar 

(174.12 PSI)

10 bar 

(145.1 PSI)

Viscosity

1000 cps. max. 

(higher on request)

Max. particle size

250 

m - To prevent damage from dirt or 

foreign matter, we strongly recommend the 
installation of a 250 

m strainer as close as 

possible to the inlet side of the meter.

Accuracy

±0.5% of Reading

Repeatibility

±0.03% of Reading

1)

 or in accordance to the value of the used flanges

Reviews: