S070
p. 1/4
www.burkert.com
Positive displacement sensor fitting
for continuous flow measurement
This positive displacement sensor fitting is specially designed for flow measurement and/or batch control of highly viscous fluids like glue, honey or oil.
This measuring element must be associated to an electronic module SE30, SE32, SE35, SE36 with hall sensor principle only, quickly
and easily connected together by a Quarter-Turn.
The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of
measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design.
The low pressure drop and high pressure rating make it suitable for both gravity and pump
(in-line)
applications.
Type 8070
Positive displacement
flowmeter
Type 8072
Positive displacement
flowmeter
Type 8075
Positive displacement
flowmeter
Type S070 can be combined for...
• DN15 to DN100
• INLINE Quarter-Turn technology
• Electronics available for indication, monitoring, trans-
mitting, On/Off control and batch control
General data
Compatibility
With electronic SE30, SE32, SE35, SE36
with Hall sensor principle
(see separate data sheet)
Wetted parts ma-
terials
Body
Rotor
Shaft
Seal
Aluminium, stainless steel
(316F)
PPS, aluminium, stainless steel
(316F)
Stainless steel
(316F)
FKM or FEP/PTFE encapsulated
Environment
Ambient temperature
0 to 60°C
(32 to 140°F)
(operation and storage)
Standards, directives and approvals
Protection class
IP66
(NEMA 6)
Directives
Pressure
Complying with article 3 of §3 from
97/23/CE directive*.
(without CE mark)
* For the 97/23/CE pressure directive, the device can only be used under following condi-
tions (dependent on max. pressure, pipe diameter and fluid).
Type of fluid
Conditions
Fluid group 1, §1.3.a
Forbidden
Fluid group 2, §1.3.a
DN
32, or DN > 32 and PN*DN
1000
Fluid group 1, §1.3.b
PN*DN
2000
Fluid group 2, §1.3.b
DN
200
Type 8076
Positive displacement
flowmeter
Complete device data
Pipe diameter
Thread connection
Flange connection
DN15 to DN100
½”; 1”; 1½”; 2”; 3”
(G or NPT)
25; 40; 50; 80 or 100 mm DIN PN16 flange
1”; 1½; 2”; 3” or 4” ANSI 150LB flange
Measuring range
Viscosity > 5 cps
Viscosity < 5 cps
2 to 1200 l/min
(0.53 to 320 gpm)
3 to 616 l/min
(0.78 to 160 gpm)
Medium tempera-
ture max.
Aluminium body: 80°C
(176°F)
Stainless steel body: 120°C
(248°F)
Medium pressure
max.
DN15
DN25
DN40/DN50
DN80
DN100
55 bar
(798.05 PSI)
(threaded process connection)
55 bar
(798.05 PSI)
1)
18 bar
(261.18 PSI)
12 bar
(174.12 PSI)
10 bar
(145.1 PSI)
Viscosity
1000 cps. max.
(higher on request)
Max. particle size
250
m - To prevent damage from dirt or
foreign matter, we strongly recommend the
installation of a 250
m strainer as close as
possible to the inlet side of the meter.
Accuracy
±0.5% of Reading
Repeatibility
±0.03% of Reading
1)
or in accordance to the value of the used flanges