![Burkert FreeLINE 8645 Supplementary Instructions Manual Download Page 13](http://html1.mh-extra.com/html/burkert-0/freeline-8645/freeline-8645_supplementary-instructions-manual_2832392013.webp)
13
EXPANDING A VALVE TERMINAL
Step 5:
Connect added modules to the existing valve
→
terminal by pressing and then turning the three
locking
pins clockwise
through 90°.
The depression of the locking pins can be facili-
tated by pressing the module onto the existing valve
terminal.
The slot is vertical.
→
Attaching more modules
Fig. 19:
Step 6:
Push the blue locking bracket over the desig-
→
nated guides.
Ensure that the connecting bracket is inserted neatly
into the guides and is pushed down parallel.
To do this, support the bracket by gripping both
→
lugs and push all the way down.
Attaching the locking bracket
Fig. 20:
Step 7:
E-rails must be re-attached.
→
Connect additional modules accordingly to the
→
FE contact.
The valve terminal is ready for use again.
Remember that any address setting on the head
module must be adjusted to the original state.
To do this, open the window on the corre-
→
sponding head module and, using the rotary
encoding switch, set the corresponding bus
address.
Valve terminal ready for use
Fig. 21: