149
LED Colour Assignments
With the classic variants
(24 V DC, 120 V AC, AS-i, DeviceNet), the setting can be changed by a service
technician, if necessary.
The parameter values and the assigned display priority are listed in
Parameter
“PRIO”
(highest) priority 1
Priority 2
Priority 3
(lowest) priority 4
1
S1
S2
S3
S4
2
S1
S2
S4
S3
3
S1
S3
S2
S4
4
S1
S3
S4
S2
5
S1
S4
S2
S3
6
S1
S4
S3
S2
7
S2
S1
S3
S4
8
S2
S1
S4
S3
9
S2
S3
S1
S4
10
S2
S3
S4
S1
11
S2
S4
S1
S3
12
S2
S4
S3
S1
13
S3
S1
S2
S4
14
S3
S1
S4
S2
15
S3
S2
S1
S4
16
S3
S2
S4
S1
17
S3
S4
S1
S2
18
S3
S4
S2
S1
19
S4
S1
S2
S3
20
S4
S1
S3
S2
21
S4
S2
S1
S3
22
S4
S2
S3
S1
23
S4
S3
S1
S2
24 *)
S4
S3
S2
S1
25
particular logic, see
Table 18:
Display priorities when position feedback overlaps - can be selected using parameter “PRIO”
*)
Factory settings: “PRIO 24”
When the position feedback is from S4 (external initiator), note whether the external initiator acts as an “Opener”
(NC contact) or as a “Closer” (NO contact) – see “Table 8: Position feedback of the external initiator (S4/S4IN)
depends on the mode of operating” on page
If the
factory setting of S4IN
(normally open contact = NO) is to be changed, this can be done for IO-Link
and büS/CANopen variants via software using the
sensor parameter “Circuit Function External Initia tor
english