ENGLISH
ENGLISH
flow rate controller 8039
1
3
2
4
5
3
1
2
0 VDC
V+
(12-30 VDC)
4.3. Version with pnp transistor output via m12 connector
4.3.6 Version with relay output
Sensor
Receiver
Load
PNP
output
pnp output
PNP transistor output
Not connected
pnp wiring of m12 fixed
connector
relay output
wiring of fixed
connector
en 175301-803
Common
Not connected
Normally Closed
Normally Open
Not connected
Not connected
(*)
(*)
4
installation
PNP
0 V
V+
V+
IN
0 V
(*)
4
5
3
1
2
0 VDC
V+
(12-30 VDC)
pin number of the m12 cable available as
an accessory (order code 438680)
Wire colour
1
brown
2
white
3
blue
4
black
5
grey
The controller is fitted with a steerable M12 fixed
connector:
Unfasten counternut. Turn the fixed connector to the
right position, but by max. 360° to avoid twisting of the
cables inside the housing. Fasten counternut using the
appropriate tool while maintening the fixed connector in
the right position.
Wiring of fixed connector m12 (12-30 Vdc power supply)
Summary of Contents for 8039
Page 1: ...Instruction Manual optical flow rate controller 8039 Bürkert 2000 Subject to technical change ...
Page 34: ...ENGLISH ENGLISH Flow rate controller 8039 NOTES ...
Page 35: ...8039 35 ENGLISH ENGLISH ...
Page 36: ...ENGLISH ENGLISH Flow rate controller 8039 ...
Page 70: ...FRANCAIS FRANCAIS Contrôleur de débit 8039 NOTES ...
Page 71: ...8039 35 FRANCAIS FRANCAIS ...
Page 72: ...FRANCAIS FRANCAIS Contrôleur de débit 8039 ...
Page 106: ...DEUTSCH DEUTSCH Durchfluss Kontroller 8039 ANMERKUNGEN ...
Page 107: ...8039 35 DEUTSCH DEUTSCH ...
Page 108: ...DEUTSCH DEUTSCH Durchfluss Kontroller 8039 ...
Page 112: ...BÜRKERT BÜRKERT Bürkert Worldwide ...