9
Description
Type 8011
To obtain a flow rate Q, this frequency must be divided by a propor-
tionality factor K according to the following formula:
Q = f/K
Depending on the version, the electrical connection is made using
a 1 m long cable or a multi-pin M12 fixed connector which position
can be adjusted.
Depending on the version, the device is equipped:
• with one NPN pulse output
• with two pulse outputs, NPN and PNP.
5.3.
Description of the name plate of
the 8011
FLOW:8011 HALL
NPN/PNP: 0,7A - 36VDC
6-36VDC
D63
PV FKM
0,3-10 M/S
00556249
W46MN
Made in France
2
4
5
6
7
8
9
11 10
3
1
1.
Supply voltage
2.
Measured value and type of the device
3.
Type of sensor
4.
Pulse output data
5.
Type of connection
6.
Flow range
7.
Conformity logo
8.
Manufacturing code
9.
Material of the seal exposed to the fluid
10.
Order code
11.
Fitting material
5.4.
Description of the name plate of
the se11
FLOW:SE11 HALL
NPN/PNP: 0,7A - 36VDC
6-36VDC
0,3-10 M/S
00559453
W46MN
Made in France
2
4
5
6
7
8
3
1
1.
Supply voltage
2.
Measured value and type of the device
3.
Type of sensor
4.
Pulse output data
5.
Flow range
6.
Conformity logo
7.
Manufacturing code
8.
Order code
English