21
Installation
8.3.3
Install control unit
For a description see chapter "Installation" in the ope
-
rating instructions for the corresponding control unit.
8.3.4
Turning actuator
The position of the ports can be seamlessly aligned by turning
the actuator 360°.
NOTE!
Damage to the seat seal or seat contour!
▶
When turning the actuator, the valve must be in the open
position.
Procedure:
→
Clamp valve body in a collet (only for valves which have not
yet been installed).
→
For control function A pressurise the pilot air port 1 with com
-
pressed air (5 bar): Valve opens.
→
Counter with a suitable open-end wrench on the wrench flat
of the nipple.
→
Place a suitable open-end wrench on the hexagon head of
the actuator.
WARNING!
Risk of injury from discharge of pressure and escaping
medium!
The body connection can loosen when rotated incorrectly.
▶
Only turn the actuator
in the specified direction
17“)!
→
Move the actuator into the required position by
turning it
counterclockwise
(seen from below).
Open-end
wrench
Image 17:
Rotatingwithopen-endwrench
Type 2101