1094 - 7
english
Vale type
Bürkert appliance socket
Control electronics
6021
2506
1094-PHR
6022, 6023, 6024, 6223
with tag connectors
2508
1094-PHR
none
1094-PMR
2821
1051
1094-PHR
2822
with wires
none
1094-PHR*
2822
with connector flags
1051
1094-PHR*
2832, 2834, 2836
with tag connectors
1050
1094-PHR
none
1094-PMR
4
INSTALLATION AND SETTING INSTRUCTIONS
4.1
Connection combinations of valves and electronics
* For proportional valve Type 2822, use only drive electronics Type 1094-
PHR with Order no. 154463
NOTE
The use of the Bürkert Type 1610 power supply is
recommended for all combinations!
When connecting the PHR electronics using the appliance
sockets 2506, 2508, 1050 or 1051, note that the cable length
must be less than 50 m; with longer cables, the 0 - 10V control
will no longer produce a full opening of the valve! This can also
apply to other signals.
The direction of the cable run can be changed in 4x 90° steps
when using the cable plug electronics type 1094-PMR.