7
5.2.2
Incoming flow under seat
The valve is closed against the medium flow by spring force
(control function A, CFA) or by control pressure (control function B,
CFB). As the medium pressure is under the seat seal, this pressure
contributes to opening of the valve.
note!
Seat seal or diaphragm subject to wear.
When the incoming flow is over the seat, powerful water
hammers may occur, especially in the case of liquid media.
▶
Do not use device for incoming flow over the seat.
▶
Observe arrow for direction of flow on the valve body.
6
Technical daTa
6.1
conformity
The device conforms to the EU directives as per the EU Declaration
of Conformity (if applicable).
6.2 standards
The applied standards, which are used to demonstrate conformity
with the directives, are listed in the EU type examination certificate
and/or the EU Declaration of Conformity (if applicable).
6.3 Type label
Type
Control function
Orifice
Seal material
Body material
Order number
Control pressure
Connection type, operating
pressure
0262 A 25,0 FKM MS
Made in Germany
0028410
W12MN
Pilot 3-6 bar
G1 P
N 0 -1 bar
english