PlusConnect™ GatesAir ZXA Installation and Operation Manual
3
Front Panel Indicators
Front panel of the PlusConnect unit
Indicator
State
Description
Power LED
On
Power is on
Power LED
Off
Power is off
Link LED
On (solid)
ARC Plus and transmitter connections are good
Link LED
Blinking
Transmitter connection is down
Link LED
Off
ARC Plus connection is down
Hardware Configuration
This step will link the PlusConnect to a specific ARC Plus unit and will identify the transmitter to which
the unit will be connected.
Important! This procedure will reset the PlusConnect to its default IP address: 192.168.0.100.
1.
Connect your PC and the PlusConnect to the same LAN.
2.
Assign your PC the IP address 192.168.0.1, with the subnet mask 255.255.255.0
3.
Use a paper clip or similar small object to press the
Config
button on the PlusConnect unit. The
power LED will blink when the unit is in configuration mode.
4.
Open a telnet session to the PlusConnect at the address 192.168.0.100 (port 23). Using
Windows, you can launch telnet by typing “telnet 192.168.0.100” from a command prompt.
(If
Telnet
is not available, go to
Control Panel/Programs and Features/Turn Windows Features
On or Off
and turn on
Telnet Client.)
5.
When prompted, enter the default password for the PlusConnect:
password.
Burk Technology
PlusConnect Harris ZX16 v1.0.6
Password:
6.
Telnet will display the main menu.