Dimensions

68,9 x 68,9 x 24 mm

Battery

lithium battery 3V, CR123A
Service life:  

45.000 locking cycles

Permissible temperature 0°– 40°C  

(no formation of condensation)

Protection class

IP 54

No. of possible codes

999.999

Code length

4 or 6 digits

Programming

Freely selectable PIN 

Fixed assigned PIN

Material

Casing: plastic (RoHs proved)

Keypad: silicon

Keypad core: Zamak (zinc alumi-

nium)

Color

grey or user specific

Locking direction

L, R, LAD

Lock attachment

raised countersunk screw

5 x 16, Torx 20

Latch

plastic bolt

Technical specifications

Functional description

Master code 

The master code starts off any programming process an can 

re-enable a lock anytime. In Freely selectable PIN mode, the 

PIN used to close is deleted once the master code has been 

entered.

Freely selectable PIN mode

In this mode, the user can enter any PIN.The user must first 

close the door. The user then enters a PIN of choice and enga-

ges the lock. The PIN entered is valid until the lock is opened 

with the same PIN.

Fixed assigned PIN mode 

In this mode, the PIN is stored in the lock. The lock only enga-

ges or disengages when the stored PIN is entered. Up to 50 

PINs can be stored simultaneously. Each stored PIN can open 

the lock, even it has been locked with a different PIN.

LED-locking status indicator   

A red flash every second in the locking indicator indicates that 

the lockis engaged. When open, the LED does not flash. This 

function is optional and can be turned on or off as desired.

Code reenter

The verification code can only be used in Freely selectable PIN 

mode. If a PIN is entered to engage the lock, it must be input 

again, when the green LED flashes for a short time to confirm. 

Only then does the lock actually engage. Simply enter the code 

again to open.

Battery warning

The low battery warning is given in two stages. If the battery 

capacity drops below the first level, the LED lights up red for 

three seconds after a PIN is entered. If the capacity falls to a 

critical level, the lock cannot be engaged at all and can only 

opened with the master code.

Note: we recommend replacing the battery as soon as the red LED 

gives the first warning.

Important information

  Each step of the configuration is confirmed as completed 

with a double flash of the LED. It is absolutely imperativ 

to only begin the next step of the configuration after this 

flashing signal.

  If you switch from one mode to the other (Freely selectable 

PIN 

 Fixed assigned PIN;  Fixed assigned PIN 

 Freely 

selectable PIN), all other functions are reset to the factory 

settings.

Caution: This does not apply to the master code.

  If the configuration step is completed incorrectly, the lock 

signals this with 8 consecutive flashes of the LED.

Caution: the lock is disabled for 45 seconds after 3 wrong inputs. A 

red flash every second indicates that the lock is currently disabled. 

This disablement can be terminated early by entering the master 

code.

The master code must always be entered as follows:

√ √  1 master code √

e. g. √ √ 1 934 716 √