background image

eBoxx EASY+

 | English

BA eBoxx EASY+ dco/sgu/hbg 081221

BURG-WÄCHTER KG

 

 Altenhofer Weg 15 

 58300 Wetter 

 Germany 

• 

www.burg.biz

      

BURG-WÄCHTER UK LTD

 

 Eurocam Technology Park 

 Chase Way 

 Bradford 

 West Yorkshire 

 England BD5 8 HW

  Control panel
   "Start"  button 

Initiates the opening process or 

opens the parcel box immediately 

if the box does not contain any 

parcels (Empty"status).

 

   Numeric  buttons 

The digits "1" – "0" are used for 

inputting the code

   "End  button" 

-  

Ends the opening process and 

closes the parcel box.

 

- Status query (occupied/empty)

   Emergency  lock

*

 

Used for opening in an emergency

  Signal LEDs

  

Delete button 

Deletes entered digits

   Note message, general error

Design

Thank you for choosing a parcel box with the  

BURG-WÄCHTER eBoxx EASY+ electronics.

eBoxx status

eBoxx instructions

Status

Meaning

Empty

parcel box is empty and can also be opened without requiring 

a code.

Full

Parcel box is occupied with at least one parcel and can be opened 

using a user or delivery provider code.

Open

eBoxx could not be locked automatically due to the child safety 

lock and remains unlocked until it is locked manually.

Activation

Open the eBoxx by pulling the door 

using the recessed grip above the 

keypad. Please remove and retain 

all of the documents supplied with 

the parcel box, store in a safe and 

secure place. 

Pull out the battery compartment 

which is located on the inside of 

the door to the bottom left of the 

electronics, remove the contact 

strip and reinsert the battery 

compartment with the required 

batteries. 

An automatic calibration process 

starts when the batteries are 

deposited. All of the LEDs on the 

eBoxx illuminate for one second and 

the eBoxx EASY+ lock is opened and 

closed several times. After calibration 

the lock is in the "Open" status. 

Please do not close the door. Perform 

the following steps immediately and 

with the door open. 

Attention: 

If the door is locked at 

this point, it can only be opened 

using the emergency lock.

The electronics adopt different status properties depending on the interaction 

with the eBoxx, and these properties have an influence on further operability. 

Below is a list of the status options and what they mean.

Note: 

A status query is performed when the "End" button is pressed. 

Details can be found in the chapter "Operation by user" on page 2.

Detailed instructions for using the eBoxx, its configuration, the 

associated app and notes on setting up the storage location 

can be found using the following link:

 

https://www.burg.biz/bedienungsanleitung- 

paketkasten-eboxx-easy-plus/ 

or directly via the QR code displayed.

Note:

 Please ensure that you are within the Bluetooth range of the eBoxx. 

The BURG-WÄCHTER KeyApp is required for commissioning the eBoxx EASY+. 

The following steps are necessary to connect the eBoxx with the app:
•  The BURG-WÄCHTER KeyApp is available for download free of charge 

from the App Store appropriate for your smartphone. Download and 

install the app. 

•  Open the app, read through the licence conditions and confirm with "OK".
•  You will now be asked to register; please enter the applicable data. 

Read and confirm the data protection guidelines and the terms of use 

and select "Register".

  

Note:

 The BURG-WÄCHTER KeyApp is GDPR compliant. No personal data 

is forwarded to BURG-WÄCHTER.

•  The KeyApp requires access to the camera and Bluetooth functionality 

to scan the QR code and connect the eBoxx. Please grant access when 

prompted.

•  Add your eBoxx in the KeyApp by clicking on the "Menu Button" (top left) 

and navigating to "eBoxx / eBoxx Setting / eBoxx Units". Press the   icon 

(bottom right) and scan the QR code supplied with your eBoxx.

•  Confirm with "Continue".
•  Enter any desired name as the name of the box and the administrator 

code. The factory set default administrator code is "1-2-3-4-5-6".

•  Confirm your selection in the KeyApp with the start button

Change administrator code

Note: 

Please carry out the following settings in the BURG-WÄCHTER KeyApp. 

Please ensure that you are within the Bluetooth range of the eBoxx.

The first step during commissioning is to change the factory set administrator 

code to a personal code. Any changes to the administrator code and the 

user code must be made with the door open. Once the locking system has 

been updated to a new code it must be checked several times keeping the 

door open.

An administrator code is required for the administration of the eBoxx. The 

administrator code is used, for example, to carry out firmware updates and to 

add or delete users. 

However, the administrator code cannot be used to open 

an eBoxx.

•  Navigate to "eBoxx / eBoxx settings / Change administrator code" in the 

smartphone app, and select the eBoxx.

•  Enter the previously valid administrator code (default factory set code  

"1-2-3-4-5-6") and the new administrator code.

•  Confirm the new administrator code by repeating the entry and confirm in 

the KeyApp with the "Start" button. 

Quick start guide

*  

Note:

 Please only remove the 

cover over the emergency lock if 

you need to open the eBoxx in an 

emergency. Opening the parcel 

box using the enclosed key is only 

intended for emergencies. This 

procedure does not change the 

status of the eBoxx and will cause 

the unit to malfunction. 

Reviews: