   Befor

e fixing the outer knob, please consider whether you wish to us

e the attached 

cover panel for the pr

ofile cylinder section. If so, 

remove the pr

otective sheet and fix 

the cover panel onto the lock section.

7

   Move the outer knob into the re

q

uired position on the shaft and 

fix

 it  

with a clearance of at least 1 mm from the 

tting using the setscrew.

8

   A function test should be performed with an open door.

C. 

Programming / function / operation

Registration of keypads with the cylinder is performed either through the keypad itself 
or by the secuENTRY softwar

e. For a cylinder to be cont

rolled via a keypad, the two 

units must paired. To pair a keypad to the cylinder, proceed as follows:

Registration via keypad

• Activate the keypad using the   key
•  Then press 

FUNC

, “Menu / Code change” is displayed

•  Now you can use the keys 1 or 2 to scroll until reaching the “Administrator” menu
•  

Confirm with 

•  Now you can use the keys 1 or 2 to scroll until reaching the administrator 

“Setup” menu

•  

Confirm with 

•  Enter the administrator code of the unit to be registered
•  “Data has been saved” is displayed after a successful registration

Attention! Make sure that no other powered secuENTRY unit is placed within 
a close proximity when registering a new keypad or a new cylinder, as such 
unit could be mistakenly paired instead of the intended one. When in doubt, 
disconnect such units from power before the registration (remove batteries).

Registration using the secuENTRY software

Please proceed according to the user manual for the corresponding software.

Opening

The secuENTRY 7100 pr

o can be operated, depending on the equipment configuration, 

using a 6 digit numerical code, the BURG-WÄCHTER KeyApp, or with fingerprints.

Opening with PIN code

• Activate the keypad using the   key
•  

Enter the 6 digit PIN code (factory-set to “1-2-3-4-5-6”). 

The display indicates “Please use rotary knob!”and the LED 

integrated in the cylinder flashes once when opening is successf

ul

• Rotate the cylinder knob

Opening with fingerprint

• Activate the keypad using the   key
•  Move the register

ed finger f

rom the top to the bottom centrally over the sensor. 

The display indicates “Please use rotary knob!”and the LED integrated in the cylinder 

flashes once when opening is successful

• Rotate the cylinder knob

Introduction

Congratulations on pur

chasing this BURG-WÄCHTER quality p

roduct! Thank you very 

much for purchasing the secuENTRY 7100 pro electronic lock system manufactured by 
BURG-WÄCHTER. This system has been developed and manufactured using the latest 
technology and achieves high security standards. The electronic cylinder can be installed 

easily without any drilling or installation of cables Full stop

 here. Suitable for any door 

prepared for pr

ofile cylinder up to a door thickness of 118

 

mm (59

 / 

59

 mm, measured 

at the central detent bolt). The electr

onic cylinder is perfectly suitable for both new 

installations and upgrades.

Contents of this user manual

A

  General 

E   Battery replacement

B   Mounting   

F

  Emergency key

C   Programming / function / operation 

G   Warranty / environment 

D   Technical data

A.

 General

Please read the entire user manual throughly before you start the installation and 
programming. Keep it in a safe place. We hope you en

j

oy your new locking system.

The secuENTRY 7100 pro cylinder can be used with the following opening media: 
• Keypad P

INCO

DE 

• Keypad 

FING

ERPR

I

NT 

• Smartdevice / App
The opening media can be obtained separately.

Administrator code / QR code

Each secuENTRY 7100 pro cylinder is provided with a QR code, which is intended both 
for registration of a keypad and for integration of a locking system by means of the 
optional secuENTRY software. 

Without an appropriate keypad, opening media 

(users) can only be registered with the cylinder by means of the optional 
software. The administrator code is also indicated on the QR code label. 

SN:

10 : 2D : 00 : 3E
30 : 42 : 25 : 00 : 00 : 60

12345 6

E1 : 25 : F3 : E2 : DB : 86 : C0 : 70 :
F7 : EA : 04 : 93 : 17 : 2E : BF : 9E

MAC:

AES:

ADM:

1

1

 Cylinder  

(SN; MAC; AES; ADM)

Attention! In case you lose your administrator code and / or your QR code, any 
reprogramming and use of administrator functions becomes impossible. Please 
store them carefully!

Our hint: The QR code can also be stored in an electronic form 

Please note that for security reasons, the factory-set administrator code must be changed
to a custom code

as a scanned file  

or a photograph on a protected data carrier.

The manufacturer assumes no liability for any injury or damage which may  
occur during the assembly or due to inappropriate handling.

B. 

Mounting

The installation of the secuENTRY 7100 pro cylinder is described below. Please read these 
installation instructions carefully before the assembly.

The cylinder is provided with a special detent system offering you a possibility to use 
the cylinder for doors up to a thickness of 118 

mm (59

 / 

59

 mm, measured at the central 

detent bolt). No prior adjustment is necessary

.

Outer side / outer knob 

Inner side / inner knob

 

Diagram of the cylinder

Cover panel

Adapter 2

Detent bolt

Adapter 1

Setscrew for 

fix

ing on the on 

the shaft

Remark

 

The base size of the cylinder is 30 mm per side. When delivered, the cylinder is 

completely collapsed (the smallest door thickness). Befor

e you insert the cylinder  

into the door

, you should adjust it to your door thickness.

Loosening and tightening of the outer and inner knobs is done by means of an 
integrated setscrew in the knob.

Attention: Never pull the inner knob completely from the shaft, as this will lead 
to damaging of the electronics! The setscrew securing the detent on the shaft 
may be loosened only lightly and it always remains in the plastic knob. The 
setscrew is intended as protection against pulling it beyond the shaft.

Proceed carefully during installation. Be certain to avoid shocks or abrupt actions.  
The lock should not be greased or oiled.

When installing the cylinder, proceed as follows:

 

1

  Take a rough measur

ement of the door thickness (incl. fittings).

2

   Pull the outer knob from the shaft, move the inner knob over the detent system 

(spacing 2.85

 

mm) to the 

r

equir

ed dimension. 

 Inner knob

Adjustment range 30 mm

Diagram of the inner knob

3

   Depending on the door thickness, you can af

fix

 an appropriate adapter on the  

outer side, in order to improve the path for the emergency key.

The following combinations are possible:

Space detent bolt / 

tting 

(

mm

)

 on the outer side

Adapter 1

Adapter 2

4

3

X: selection 
–:  not provided

44

 – 53

X

5

4

 – 

6

0

X

X

Tab. 1: Space detent bolt / 

tting [mm] on the outer side and the required adapter.

2,

9

 × 1

6

Adapter 2

M2 × 10

Adapter 1

Illustration of 
adapter 

tting

4

   

I

nsert the secuENTRY 7100 pro cylinder from the outside of the door to the 

inside through the mortise lock in the door and then tighten the detent bolt.

5

   Push the inner knob over the shaft until attaining the re

q

uired dimension.  

Please make sure that the clearance between the rotary knob and the door  

tting is at least 1 mm. Then 

fix

 the rotary knob using the setscrew.

Opening with BURG-WÄCHTER KeyApp

•  Hold your smart device in front of the cylinder knob and press the opening 

key of the KeyApp.

•  

The LED integrated in the cylinder flashes once when opening is 

successful.

• Rotate the cylinder knob.

You can download the BURG-WÄCHTER KeyApp from the App Store or the Google Play 
Store

. For t

his purpose, simply enter the search item “secuENTRY” or “KeyApp”.

Compatible with Samsung Galaxy S4, S4 mini, S5 and S5 mini f

rom Andr

oid 4.3 KitKat 

or 5.0 Lollipop, Apple iPhone 4S, 5, 5S, 6, 6S f

r

om IOS 8.1.3.

Please check under: 

www.burg.biz/secuentry/description

 whether additional 

smartphones are compatible with the App.

D.

 Technical data

Number of user codes

ma

x

. 2000

Mechanical emergency opening

Blocking times

After 3 

x

 wrong code is entered 1 minute, 

then always 3 minutes

Power supply

2

 x

 

MIGNON 

LR

6

 ALK

ALI

NE

Date / time

Calendar

*

Timer

*

Permanent timer

*

Hotel function / guest code

*

Hotel function / transponder

*

Time limited code

*

Smart Device / KeyApp

*

Smart Device / KeylessEntry

*

Apple Watch / KeyApp

*

Number for history

*

2000

*

 

F

unctions with the optional secuENTRY software only

Additional functions using the optional secuENTRY software, for example:

•  User administration
•  Timer and calendar functions
• Assignment of authorizations

Optical signalling

Optical signalling in the form of a LED is incorporated in the 

knob on the outer  

side of the door. This LED informs you on the following:
• 1 × brief: cylinder coupled
• 2 × brief: cylinder uncoupled
• 1 × brief, 1 × long, 2 sec. pause, repeating: lock in programming mode
•  5 × brief, 2 sec. pause, repeating in 20 sec.: battery in cylinder empty

E.

 Battery replacement

1

   

Using the attached hex ke

y, loose the top setscrew on the cylinder cover

. It can be 

turned out only up to the opening of the cover and will not fall out.

2

  Snap the cover open.

3

   Replace the batteries. Make sure the batteries are inserted with a correct polarity, 

indicated at the marked point on the housing. Replace the cover. 

F.

 Emergency key

Using the mechanical key, you can gain access in case of failure of the system.

1

   Swing the emergency key open and then insert it into the indicted  

slot in the cover panel.

2

   Tur

n the key 90

 

° clockwise. If 

r

equir

ed, move the outer knob slightly to the  

right and left in order to release the mechanism.

3

   Turn the outer knob. The lock opens when fully turned.

Turn the key to its initial position and take it out. To close the emergency lock,  
the knob should be turned twice fully in both directions.

G.

 Warranty / environment

Warranty

In o

rder to be able to provide you with r

eliable high quality p

roducts and optimal  

support when you need servicing or repair, we need you to present faulty or defective 
devices to your vendor together with a valid administrator cod

e and the QR code(s),  

with the original purchase document attached.

When you return a device component based on your right of withdrawal from the 
purchase agr

eement, such component shall be adjusted to factory settings an

d the  

seal on the cylinder and on the knob shall be intact. In case o

f non-compliance with  

this, the warranty becomes invalid.

Disposal of device

Dear customer, 
please help us avoid unnecessary waste. Should you intend to dispose of this device 
at any time, please remember that many components of this device contain valuable 
materials, which can be recycled.

Please be aware that electrical and electronic e

q

uipment and  

batteries shall not be disposed of as household waste, but rather 
collected separately. Please obtain information on the collecting  
points for batteries and electrical waste from the responsible  
authority of you municipality.

About interference from Bluetooth devices

Bluetooth devices use the same fr

equency band (2.4GHz) as 

W

iFi devices. This can cause 

interference leading to errors or even to communication failur

e. In such case, any devices 

not r

equi

red should be kept disconnected from power.

 Montage- und Bedienungsanleitung
 Assembly and User Manual

 Download: www.burg.biz
 Download: www.burg.biz
 Download: www.burg.biz
 Descarga: www.burg.biz
 Download: www.burg.biz 
 Download: www.burg.biz

 Download: www.burg.biz
 Download: www.burg.biz
 Ladattava tiedosto: www.burg.biz
 λήψη: www.burg.biz
 İndir: www.burg.biz
 Descărcare: www.burg.biz

 Pobieranie pliku: www.burg.biz
 Stáhnout: www.burg.biz
 Letölthető: www.burg.biz
 Download: www.burg.biz
 Download: www.burg.biz
 Download: www.burg.biz

 загрузка: www.burg.biz
  Download (зареди):  

www.burg.biz

 Download: www.burg.biz

BURG-WÄCHTER KG 

Altenhofer Weg 15 

 58300 Wetter 

 Germany 

[email protected] · www.burg.biz

BW_pro 7100 Zylinder_BA_sE_010100 hbg/eba 11/2017

BURG-WÄCHTER KG hereby declares that this device complies with Directive 

2014/53/EU, (RED) 2014/30/EU, (EMC) and 2011/65/EU (RoHS). The full text 

of the EU Declaration of Conformity can be found on the following website
www.burg.biz

Transmitting power and frequency range:

Bluetooth Low Energy

Maximum Transmit Output Power 7,5dBm
Frequency usage range 2,402GHz … 2,483 GHz

Reviews: