Burco 76500 Instructions For Use Manual Download Page 12

Burco Appliances Limited

A MEMBER OF THE GLEN DIMPLEX GROUP

Talbot Road, Mexborough, South Yorkshire, S64 8AJ 

Tel

01709 577120 

Fax 

01709 587510

Email

[email protected] 

Burco Appliances products are intended for commercial use as detailed in these

instructions. We follow a policy of continuous improvement in product quality and

design. The company, therefore reserves the right to change the specification of

its models at any time. 

CP76500MUK

Guarantee

This water boiler is guaranteed for a period of 12 months from the date of

purchase against defective materials or faulty workmanship. This guarantee is given
subject to the water boiler being used in accordance with the instructions on the
supply voltage marked on it and to the usual fair wear and tear conditions. The
guarantee does not cover consequential damage arising out of any failure
acceptable under guarantee, nor does it cover damage resulting from misuse,
accident or unauthorised alterations to the water boiler.

This guarantee, in no way diminishes the buyer’s statutory rights. Please fill in

and return the tear off section to register the guarantee with Burco.

A5 Autofill counter top ib  6/4/06  4:37 pm  Page 12

Summary of Contents for 76500

Page 1: ...rmal The water boiler must be used on a flat level surface Boil and discard the water twice before general use www burco co uk Autofill counter top water boiler For Burco wall mounted boilers 76500 76...

Page 2: ...rature between 10 C and 40 C Mains lead The mains lead should reach from the wall socket the autofill water boiler without straining the connections Do not let the cord hang over the edge of the table...

Page 3: ...S1363 13A plug In the event of replacing a fuse a 13 amp fuse approved by ASTA or BSI must be used If the plug is not suitable for your socket then the plug must be cut off and disposed of safely An a...

Page 4: ...er boiler and wipe over all surfaces with a clean cloth 2 Check that the voltage on the rating plate of your appliance corresponds with your electricity supply which must be A C Alternating Current 3...

Page 5: ...ed water connection fitting to water inlet screw fitting and when secure attach the pipe B Tightly attach other end of water connection hose to mains water supply Ensure all pipes are suitably insulat...

Page 6: ...l water boiler still in desired position Do not replace the stainless steel cover so that you are able to mark the position of the hole on the work surface with a suitable marker Remove drip tray and...

Page 7: ...ill appears dead contact Burco helpline Cleaning WARNING Disconnect from the electrical supply before cleaning and allow the water boiler to cool IMPORTANT Do not immerse the water boiler in water or...

Page 8: ...flashing when the boiler is up to temperature leave unit for 10 minutes do not leave descaler in water boiler for more than 30 minutes Drain water through main dispensing tap to ensure tap is descaled...

Page 9: ...MPORTANT Do not use any abrasive cleaning fluids or materials IMPORTANT Do not use this appliance in an area a water jet can be used If your autofill boiler still does not reset call our Helpline on 0...

Page 10: ...s descaling detected likely scale build up ASAP See descale process on page 8 Red indicator flashes 3 times Unit below 60 C Possibly due to Check boil dry thermostat has been reset boil dry protection...

Page 11: ...warranty Helpline 0870 060 2618 If you have any difficulty with your appliance please check the items on the list below Does your autofill water boiler have power going into the unit Have you tried de...

Page 12: ...period of 12 months from the date of purchase against defective materials or faulty workmanship This guarantee is given subject to the water boiler being used in accordance with the instructions on t...

Reviews: