background image

 

THE URN TO COOL 

 

THIS URN IS NOT WATERPROOF 

 

DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THE APPLIANCE, 

OR USE A WATER JET IN THE VICINITY OF THE APPLIANCE 

4.1.6 Exterior 

Clean with water and detergent. Do not use harsh abrasive cleaners as this could damage the surface 

finish. 

4.1.7 Interior 

Brush any scale or sediment from the element and rinse thoroughly with clean water. 

4.1.8 Descaling 

In  hard  water  areas  scale  will  form  on  the  element  and  interior.  This  will  adversely  affect  the 

operation  of  the  urn  if  allowed  to  accumulate.  Descale  on  a  regular  basis,  using  a  proprietary 

descaling agent recommended for stainless steel kettles. Follow the instructions provided with the 

descaling product. 

Scale build-up can also cause the tap to drip. If this should occur, turn off the power supply and 

remove the plug. Empty the urn and allow it to cool. Unscrew the top of the tap from the body. 

Wipe, scrape and break the scale away from the rubber flexible seal and from the sealing surfaces 

inside the plastic body of the top. Reassemble, tightening the top of the tap until the white dot is 

towards the front. 

4.1.9 Trouble-shooting 

 

Fault

 

Possible Cause

 

Remedy

 

 
 

The appliance does 
not operate.

 

No Power to the 
appliance 

Check supply socket is switched on.

 

 

Check fuse and circuit breaker. 

 
Check green power indicator is illuminated.

 

 

Thermostat or 
element faulty.

 

      
Replace thermostat or element. 

Summary of Contents for 444448528

Page 1: ...444448528 444448529 444448530 Glen Dimplex UK Ltd trading as Glen Dimplex Heating Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Web www gdhv com Glen Dimplex Europe Ltd Airp...

Page 2: ...efore Connection to Power Supply 4 3 2 2 Location 4 3 2 3 Electrical Connection 5 4 0 User Guide 6 4 1 Filling 6 4 1 1 Controls 6 4 1 2 Safety tap 7 4 1 3 After use 7 4 1 4 Protective Cutout 7 4 1 5 C...

Page 3: ...s put water in the urn before switching on lift the lid and Fill with the desired amount of water Do not fill above the max capacity mark 1 2 Warning If the urn is over filled there is a risk that boi...

Page 4: ...h European Community Directives CE for household and similar electrical appliances and Gas appliances where applicable This appliance conforms to European Directive 2009 125 EC regarding Eco design re...

Page 5: ...following Wire Colour Wire Name Wire Code Green Yellow Wires Earth E Blue Wire Neutral N Brown Wire Live L The wire which is coloured green and yellow must be connected to the terminal in the plug wh...

Page 6: ...EMOVE THE PLUG WHEN NOT IN USE BEFORE CLEANING AND BEFORE REPLACING ANY PARTS 4 1 Filling Lift the lid and fill to the desired level Do not fill above the MAX indicator Take care not to under fill as...

Page 7: ...ever through 180 Open the tap by depressing the lever tap to the horizontal position Close the tap by returning the lever to the vertical position 4 1 3 After use Turn the control knob to 0 and discon...

Page 8: ...ry descaling agent recommended for stainless steel kettles Follow the instructions provided with the descaling product Scale build up can also cause the tap to drip If this should occur turn off the p...

Page 9: ...9 5 0 Wiring Diagram Electric Catering URN...

Page 10: ...20290 Thermostat knob kit 1 62100 Thermostat control knob 1 082626774 Neon green 1 082626777 Tap assembly 1 082626760 Tap actuator 1 60109 Handle assembly 2 62657 Reset rod tube 1 62784 Conical spring...

Page 11: ...nor does it cover damage resulting from misuse accident or unauthorized alterations to the appliance Proof of purchase will be required In any communication with the supplier or manufacturer quote the...

Page 12: ...and guarantee terms without prior notice due to a policy of continuous improvement To speak to customer services please contact UK ROI Glen Dimplex UK LTD Millbrook House Grange Drive Hedge End Southa...