8
THE URN TO COOL
➢
THIS URN IS NOT WATERPROOF
➢
DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THE APPLIANCE,
OR USE A WATER JET IN THE VICINITY OF THE APPLIANCE
4.1.6 Exterior
Clean with water and detergent. Do not use harsh abrasive cleaners as this could damage the surface
finish.
4.1.7 Interior
Brush any scale or sediment from the element and rinse thoroughly with clean water.
4.1.8 Descaling
In hard water areas scale will form on the element and interior. This will adversely affect the
operation of the urn if allowed to accumulate. Descale on a regular basis, using a proprietary
descaling agent recommended for stainless steel kettles. Follow the instructions provided with the
descaling product.
Scale build-up can also cause the tap to drip. If this should occur, turn off the power supply and
remove the plug. Empty the urn and allow it to cool. Unscrew the top of the tap from the body.
Wipe, scrape and break the scale away from the rubber flexible seal and from the sealing surfaces
inside the plastic body of the top. Reassemble, tightening the top of the tap until the white dot is
towards the front.
4.1.9 Trouble-shooting
Fault
Possible Cause
Remedy
The appliance does
not operate.
No Power to the
appliance
Check supply socket is switched on.
Check fuse and circuit breaker.
Check green power indicator is illuminated.
Thermostat or
element faulty.
Replace thermostat or element.