FACTORY SET VOLTAGE 115 V

TO CHANGE THE VOLTAGE :

Before changing the 

voltage connection:

A) Ensure the power to

the pump is disconnected. 

B) Open motor junction box cover.

C) Please select the up knob

position for 115V or down

knob position for 230V.

D) Connect to appropriate voltage.

E) Close motor junction box.

Your pump has been carefully packaged at the 

factory to prevent damage during shipping. 

However, occasional damage may occur due 

to rough handling. 

Carefully inspect your 

pump

 for damages that could cause failures. 

Report any damage to your carrier or your point 

of purchase.

INSTALLATION

INSTRUCTIONS

JET PUMPS 

MODELS

506121S

(VERSION W 2015)

AND OTHER PRODUCTS

506127S, 506128S

506131S, etc.

Please read these 

instructions

 carefully. 

Failure 

to comply to 

instructions and 

designed

 operation of 

this system,

 may

 void 

the warranty.

© 2018 BURCAM  Printed in Canada 506662

 Discharge  connection

PRIMING PROCESS

Follow all these inside step by step instructions to install your pump. Use teflon tape on 

all threads. (1) Fill the suction line with water and connect it to the suction inlet.  

(2) Remove the priming plug and fill the pump body with water. (3) Screw the plug to the

priming inlet. (4) Turn the power on. The pump should deliver water to the plumbing line

within 30 seconds. If not, unplug the pump and repeat the process at step 2.

2-3

4

Suction connection

1

2190 Dagenais Blvd. West

Laval (Quebec)

Canada

H7L 5X9

Tel. : 514.337.4415

Fax : 514.337.4029

[email protected]

see us at

 

www.burcam.com

Summary of Contents for 506121SW

Page 1: ...W 2015 ANDOTHERPRODUCTS 506127S 506128S 506131S etc Please read these instructions carefully Failure to comply to instructions and designed operation of this system may void the warranty 2018 BURCAM...

Page 2: ...750929 6 x 1 1 1 well seal elbow 750860 2 1 male adaptors 750865 or 750871 8 1 stainless steel clamps 750885 Teflon tape Tank installation Desired length of 1 braided hose 750919 to link up from pump...

Page 3: ...tion should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pip...

Page 4: ...close as possible to the basement wall Locate the suction inlet in the front of the pump body Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pum...

Page 5: ...ir at the snifter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now properly precharged Run the pump through a few cycles to verify that it works properly Other...

Page 6: ...voltage See above drawing on right The pressure switch setting start stop 20 40 or 30 50 has been made at the factory Adjustments may be done to give other operating pressures Adjustment or modificati...

Page 7: ...well seal and piping into well casing STEP 2 Cut poly pipe and install the check valve Check valve close to pump STEP 3 Insert well seal elbow through the seal and attact to pipe STEP 7 You may insta...

Page 8: ...djust air pressure To home s plumbing distribution line Pressure switch 1 4 connection if not included with the pump Pressure gauge 1 4 connection Drain valve 1 2 connection 1 MNPT or 3 4 FNPT connect...

Page 9: ...ump bracket 20 506383 Motor flange cap screw 21 506074GP Fan cover Ref Part Description 22 506073W Motor fan 23 506072GP Motor end bell 24 506385 Wave spring washer 25 350335 Motor bearing fan side 26...

Page 10: ...ir bubbles in water cavitation Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot va...