FIG. 6 LIMIT THERMOSTAT TERMINALS

SERVICE (cont.)

LIMIT THERMOSTAT

Location:

 

The limit thermostat is located inside the hood on 

the right side of the tank lid.

Test Procedures:

1.  Disconnect the brewer from the power source.

2.  Disconnect the blue/black and black wires from 

the limit thermostat.

3.  Check for continuity across the limit thermostat 

terminals with an ohmmeter.

If continuity is present as described, the limit thermostat 

is operating properly.

If continuity is not present as described, replace the 

limit thermostat.

P2414

FIG. 5 LIMIT THERMOSTAT

P1800

BLK to Tank

Heater

BLU/BLK to Control 

Thermostat

TANK HEATER

Location:

 

The tank heater is located inside the tank 

and secured to the tank lid.

Test Procedures:

1.  Disconnect the brewer from the power supply.

2.  Check voltage across the black and white wires 

with a voltmeter. Plug-in the brewer to the power 

source. The indication must be 120 volts ac.

3.  Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4

If voltage is not present as described, refer to the Wir-

ing Diagrams and check wiring harness.

4.   Disconnect the black wire and the white wire  

from the tank heater terminals.

5.   Check for continuity across the tank heater ter-

minals.

P2414

FIG. 7 TANK HEATER

Removal and Replacement:

1.  Remove all wires from limit thermostat termi-

nals.

2.  Carefully slide the limit thermostat out from under 

the retaining clip and remove limit thermostat.

3.  Carefully slide the new limit thermostat into the 

retaining clip.

4.  Refer to Fig. 6 when reconnecting the wires.

39064 042806

Summary of Contents for VPR APS

Page 1: ...RVICE MANUAL BUNN O MATIC CORPORATION OF CANADA 280 INDUSTRIAL PARKWAY SOUTH AURORA ONTARIO L4G 3T9 PHONE 905 841 2866 FAX 905 841 2775 39064 7000A 05 09 2006 Bunn O Matic Corporation www bunn com VPR...

Page 2: ...5 841 2866 or by writing to 280 Industrial Parkway South Aurora Ontario L4G 3T9 2 if requested by Bunn shipping the defective equipment prepaid to an authorized Bunn service location and 3 receiving p...

Page 3: ...ATIONAL AND LOCAL ELECTRICAL CODES KEEP COMBUSTIBLES AWAY FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL INCLUDING THE LIMIT OF WARRANTY AND LIABILITY B...

Page 4: ...ter into the screened area on top of the brewer 7 When water has stopped flowing from the funnel let water in the tank reheat to the proper temperature 8 Empty the dispenser The brewer is now ready fo...

Page 5: ...BLEM Water is not hot Spitting or excessive steaming PROBABLE CAUSE 1 Limit Thermostat CAUTION Do not eliminate or bypass limit thermostat thermal cut off Use only BOM replace ment part Limit Thermost...

Page 6: ...eposits Delime as required The dispenser must be com pletely empty before starting a brew cycle BUNN paperfiltersmustbeused for proper extraction A fine or drip grind must be used for proper extractio...

Page 7: ...the funnel Brewer is making unusal noises PROBABLE CAUSE REMEDY 1 Funnel Loading 1 Tank Heater The BUNN paper filter must be centered in the funnel and the bed of grounds leveled by gently shaking Re...

Page 8: ...the power source when servicing except when electrical tests are required and the test procedure specifically states to plug in the brewer COMPONENT ACCESS WARNING Disconnect the brewer from the power...

Page 9: ...fully counter clockwise 8 Disconnect the brewer from the power source Ifvoltageispresentasdescribed reinstallthecapillary tube into the tank to the line 4 5 above the bulb the control thermostat is o...

Page 10: ...secured to the tank lid Test Procedures 1 Disconnect the brewer from the power supply 2 Check voltage across the black and white wires with a voltmeter Plug in the brewer to the power source The indic...

Page 11: ...nut securing the sprayhead tube to the hood Set aside for reassembly 5 Remove the eight 8 32 nuts securing the tank lid to the tank 6 Remove the tank lid with limit thermostat spray head tube and tan...

Page 12: ...HI WHI BLK 33769 0000C 03 06 2001 BUNN O MATIC CORPORATION UPPER WARMER WHI BLK 120 VOLTS A C 2 WIRE SINGLE PHASE 60 HZ WHI RED VIO LIMIT THERMOSTAT BLU BLK SW THERMOSTAT ON OFF SWITCH ON OFF SWITCH W...

Reviews: