P1263

Location:

 

The control thermostat is located inside the trunk 

on the left side of the component bracket.

Test Procedures:

1.   Disconnect the brewer from the power source.

2.  With a voltmeter, check the voltage across the 

blue wire on the control thermostat and the white 

wire on the tank heater. Connect the brewer to the 

power source. The indication must be:

 

a) 100 volts ac for two wire 100 volt models.

 

b) 120  volts ac for two wire 120 volt models.

3.  Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, refer to the Wiring 

Diagrams and check the brewer wiring harness.

4.  Gently remove the capillary bulb and grommet 

from the tank.

5.  With a voltmeter, check the voltage across the black 

wire of the control thermostat and the white wire 

on the tank heater when the control thermostat is 

turned "ON" (Fully clockwise). Connect the brewer 

to the power source. The indication must be:

 

a) 100 volts ac for two wire 100 volt models.

 

b) 120 volts ac for two wire 120 volt models.

6.  Voltage must not be present when the thermostat 

is turned to the "OFF" position.

P1161.40

SERVICE (cont.)
CONTROL THERMOSTAT

7.   Disconnect the brewer from the power source.

If voltage is present as described, reinstall the capillary 

tube into the tank to the line 4.5" above the bulb, the 

control thermostat is operating properly.

If voltage is not present as described, replace the 

thermostat.

Removal and Replacement:

1.   Remove wires from control thermostat leads.

2.  Remove the thermostat capillary bulb by firmly 

pulling up on the capillary at the tank lid. This will 

disengage the grommet from the tank lid.

3.  Remove the one #8-32 screw securing the con-

trol thermostat to the component bracket in the 

trunk.

4.  Slide the grommet to the line 4.5" above the bulb 

on the new capillary tube.

5.   Insert the capillary bulb through the hole in the 

tank lid and press the grommet firmly and evenly 

so that the groove in the grommet fits into the tank 

lid.

6.  Carefully bend the capillary tube so that the tube 

and bulb inside the tank are in the vertical posi-

tion.

NOTE -  The capillary tube must be clear of any electri-

cal termination and not kinked.

7.  Using one #8-32 screw secure the control thermo-

stat to the component bracket inside the trunk.

8.  Refer to Fig. 3 when reconnecting the wires.

9.  Adjust the control thermostat as required.

FIG. 2 CONTROL THERMOSTAT

FIG. 3 CONTROL THERMOSTAT TERMINALS

46721  052512

BLU to BLU Lead from 

Limit Thermostat

BLK to BLK Lead from 

Tank Heater

Summary of Contents for VP17 Series

Page 1: ...VP17 Series SERVICE REPAIR MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 46721 0000A 05 12 2012 Bunn O Matic Corporation ...

Page 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no cha...

Page 3: ...est procedure specifically states to plug in the brewer COMPONENT ACCESS WARNING Disconnect the brewer from the power source before the removal of any panel or the replace ment of any component All components are accessible by the removal of the top cover and front inspection panel and warmer assemblies The top cover is attached with one 4 40 screw The front inspection panel is attached with four ...

Page 4: ...ROL THERMOSTAT 7 Disconnect the brewer from the power source Ifvoltageispresentasdescribed reinstallthecapillary tube into the tank to the line 4 5 above the bulb the control thermostat is operating properly If voltage is not present as described replace the thermostat Removal and Replacement 1 Remove wires from control thermostat leads 2 Remove the thermostat capillary bulb by firmly pulling up o...

Page 5: ...rminals Ifcontinuityispresentasdescribed thelimitthermostat is operating properly If continuity is not present as described replace the limit thermostat Removal and Replacement 1 Remove all wires from limit thermostat termi nals 2 Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat 3 Carefully slide the new limit thermostat into the retaining clip 4 R...

Page 6: ...o Fig 7 when reconnecting the wires P1918 SERVICE cont ON OFF WARMER SWITCH Location The ON OFF warmer switch es are located on the front of the hood Test Procedure 1 Disconnect the brewer from the power source 2 Viewing the switch from the back remove the white wire from the upper terminal and the black wire from the center terminal 3 With a voltmeter check the voltage across the white wire and t...

Page 7: ...t all three parts aside for reassembly 2 Disconnect the black wire on the limit thermostat from the tank heater switch and disconnect the blue wire from the limit thermostat to the control thermostat 3 Disconnect the black wire and the white wire from the tank heater terminals 4 Remove sprayhead and the hex nut securing the sprayhead tube to the hood Set aside for reas sembly 5 Remove the eight 8 ...

Page 8: ...roperly If continuity is not present as described replace the tank heater switch Removal and Replacement VP17 1 Remove the tank inlet fitting securing fill basin to the tank lid Remove fill basin and gasket Set all three parts aside for reassembly 2 Removesprayheadandhexnutsecuringsprayhead tube to the hood Set aside for reassembly 3 Disconnect the wires on the limit thermostat and the tank heater...

Page 9: ...to the tank lid Remove fill basin and gasket Set all three parts aside for reassembly 2 Disconnectthetwoblackwiresfromthetankheater switch 3 Remove the plastic facenut hex facenut and the switch indicator guard bracket that secures tank heater switch to the brewer Remove switch and discard 4 Insert new tank heater switch through the hole in the lower left of the control panel and secure with swtic...

Page 10: ...resent as described reconnect the white wire and white red brown black or violet wires on the warmer element P1164 If continuity is not present as described replace the warmer element Removal and Replacement 1 Remove the three 4 40 screws securing the warmer assembly to the brewer 2 Lift the warmer assembly from the brewer 3 Disconnectthetwowiresfromthewarmerelement terminals 4 Remove the two 8 32...

Page 11: ... GND SINGLE PHASE BLK BRN BLK BRN BLK BLK VIO VIO VP17 3 2 SIDE WARMERS 1320W BLK TANK HEATER L1 GRN BLK BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER 50W WHI BLK LIMIT THERMOSTAT WHI REAR WARMER WHI WHI P3 P1 VIO BLK VP17 2 TOP WARMER ASSY VIO WHI ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH NOT USED ON LATE MODELS WITH SIDE WARMERS FRONT WARMER REAR WARMER ...

Page 12: ... VOLTS AC 2 WIRE SINGLE PHASE BLK BRN BLK BLK VIO 2 TOP or SIDE WARMERS AUXILIARY OUTLET NOT AVAILABLE ON VP17 3 BLK TANK HEATER L1 GRN BLK HEATER SWITCH BLK BLU READY INDICATOR BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER WHI BLK LIMIT THERMOSTAT BLK WHI REAR WARMER WHI WHI P3 P1 VIO BLK 1 TOP WARMER VIO WHI GRN 200 WATT MAXIMUM WHI BLK BLK ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH ...

Page 13: ...SE BLK BRN BLK BLK VIO BLK TANK HEATER L1 GRN BLK HEATER SWITCH BLK BLU READY INDICATOR BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER WHI BLK LIMIT THERMOSTAT BLK WHI REAR WARMER WHI WHI P3 P1 VIO BLK 1 TOP WARMER VIO WHI GRN 200 WATT MAXIMUM WHI BLK BLK ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH 2 TOP or SIDE WARMERS NOT USED ON LATE MODELS WITH SIDE WARMERS AUXILIARY OUTLET NOT AVAILAB...

Page 14: ... or SIDE WARMERS NOT USED ON LATE MODELS WITH SIDE WARMERS 10862 0001L 01 07 1995 BUNN O MATIC CORPORATION 220 240 VOLTS AC 2 WIRE GND SINGLE PHASE BLK L1 L2 BLK RED MAIN ON OFF SWITCH Late Models only 46721 052512 ...

Page 15: ...Page 15 46721 052512 ...

Page 16: ...Page 16 46721 052512 ...