22
TROUBLESHOOTING (cont.)
Problem
Probable Cause
Remedy
(A) Replace the brew funnel and
press the appropriate brew start
switch.
(B) Make sure funnel is seated prop-
erly in the funnel rails.
(A) Allow the “Dispose Grounds”
indicator to light before removing
brew funnel.
(B) Allow the “Clean Cycle” indicator
to extinguish before removing brew
funnel.
Brew fresh coffee.
Select only one dispense strength
at a time.
Run a complete rinse cycle.
Wait for “Clean Cycle” indicator to
extinguish.
Brew funnel was removed prior to
the start of the brew cycle
Funnel lock engaged
Reservoir contents are low
Two or more dispense strengths have
been selected
Time limit has expired between rinse
cycles
Clean or rinse cycle is running
“Autobrew ON” indicator extin-
guishes without brewing
Brew funnel cannot be removed
Left/Right coffee will not dispense
1. “Left/Right Low” indicator lit
2. No indication
3. “Clean Tonight” indicator fl ash-
ing
4. “Clean Cycle” indicator lights
35352 121405