Page 9
TANK DRAINING
FACTORY BLOWOUT MODE - My Café AP
1. Disconnect the power and water supply to brewer.
Allow brewer to cool before proceeding.
2. Remove the top and rear covers. Place brewer next
to a sink.
3. Direct the drain hose into sink. Remove clamp and
plug. FIG. 9-1
4. Allow water to syphon out of tank. NOTE: A small
amount of water will remain below the tube level.
If necessary, insert a syphon hose through one of
the grommet holes to remove remaining water.
5. Replace the plug and clamp.
6. Replace the covers and tighten screws.
FIG 9-1
41167.2 080311
Summary of Contents for My Cafe AP
Page 15: ...Page 15 ...