![Bunn Liquid Autofill Kits Installation Instructions Manual Download Page 5](http://html.mh-extra.com/html/bunn/liquid-autofill-kits/liquid-autofill-kits_installation-instructions-manual_2830548005.webp)
5
INSTRUCTIONS (Continued)
37570.2 081811
29. Apply power to machine and turn on water and syrup supply. Refer to the Programming section of this manual in the Refill
Threshold section to check refill for proper operation.
30. At the threshold screen, with no product in the hopper, confirm the number on the left (top) of the screen is around 250. The
number on the right of the screen is factory set to 155. The factory set point should not need any adjustment.
31. After confirming that both hoppers are reading about 250 for the threshold, proceed to the next screen to test the refill circuit.
32. At the test refill screen, select yes.
33. The Activate Valve screen will allow you to test the pumping and refill circuit. Press and hold the ULTRA button to activate the left
refill system. Confirm that the left side is filling when the ULTRA button is pressed. Release the ULTRA button to stop the filling
process. Repeat this process for the right side by pressing the ICE button to test. Check for leaks at the hoses while pumping
system is running.
34. Run each side until water and product are flowing freely.
35. Take a sample from each side (directly from the tubes going into the hopper) to check for proper brix ratio.
Set up and calibration:
36. Make adjustments to the brix/ratio by turning the screw/valve adjuster on the
water side at the top of the motor cover (at right). Turning the screw clockwise will
decrease the water flow. Counter-clockwise will increase the water flow. The flow
rate on the syrup side is not adjustable.
37. Once the testing is complete, exit the programming menu.
38. The auto fill feature can be turned on by pressing the auger button for each side until
the display reads “AUGER REFILL ON”.
NOTE: Some models also include a “Delay Refill” option. This feature is used to dose in
small amounts of new product while delaying between doses. This can help the already
frozen product from becoming deluted and not ready to serve. These delay and fill times
are to be determined and set based on each application as desired by the end user.