13
PROGRAMMING THE DISPENSER (Cont.)
Program Mode
: Used to change or enter new set-up values.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will
display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use
the Increase (+) and Decrease (-) switch to adjust the values.
Tank Temperature
Default = 180°F (82°C)
Range = 120° - 200°F (49 - 93°C)
Ready Temp = Tank Temp minus 10°F
(~5.5°C)
LED DISPLAY
PROGRAM MODE
DESCRIPTION
Dispense Ratio
Set Coffee Mix Ratio
Default = 30:1
Range = 20 Max / 100 Min
Software Version
Displays Software Version # -
Exits To Home View After 3 Seconds.
Portion Volume
Set Portion Dispense Volume
Default = 0.0, Disabled
Range = 16.0 / 40.0 Oz.
(0.5 / 1.2 L)
Dispense Total
Hold Decrease Switch to Reset Total
to Zero. 0.0 Gal (0.0 L)
Rinse Alarm Timer
Default = OFF (Rinse Alarm Disabled)
Range = 8 - 24 hrs
MENU
(-)
(+)
0 1 8 0
MENU
(-)
(+)
1
3 0
MENU
(-)
(+)
XX.X
MENU
(-)
(+)
2
0
0.
MENU
(-)
(+)
3
0
0.
MENU
(-)
(+)
4
0
0.
44806.1 081211