background image

INSTALLATION & OPERATING MANUAL

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

www.bunnomatic.com

IMIX

®

-3S

  IMIX

®

-5S

38526.0000C   09/07  ©2005  Bunn-O-Matic Corporation

To obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, 

and the quickest way to obtain the catalog. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper 

copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.

Summary of Contents for iMIX-3S

Page 1: ... IMIX 3S IMIX 5S 38526 0000C 09 07 2005 Bunn O Matic Corporation To obtain the Illustrated Parts Catalog visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the catalog Contact Bunn O Matic Corporation at 1 800 286 6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U S Postal Service ...

Page 2: ... by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified abo...

Page 3: ...he Basic Plumbing Code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA For models installed outside the U S A comply with the applicable Plumbing SanitationCode USER NOTICES The notices on this dispenser should be kept in good condition Replace unreadable or damaged labels 00831 0000 00656 0000 ...

Page 4: ...er is disconnected from the power source If plumb ing has been hooked up the dispenser is ready for Initial Fill Heat PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi 138 and 690 kPa This water source must be capable of producing a minimum flow rate of 4 5 fl oz 133 1 ml per second A shut off valve should be installed in t...

Page 5: ...ry 5 seconds Once the cause of the refill error has been investigated see the troubleshooting guide in the Operating and Service Manual and cured the system can be reset by placing the Rinse Run switch in the programming center position momentarily RINSE TIMERS The dispenser is shipped from the factory with the rinse timers disabled To enable the rinse timers remove power from the dispenser remove...

Page 6: ...e rinse run switch to the run position after hopper motor speed adjustments are complete For IMIX 3S only 5 Once any of the three hopper motors has been programmed to the desired speed either or both of the other hopper motors can be set to the same speed as follows a Place the rinse run switch in the center program position b Press and hold the dispense switch that has been programmed for the cor...

Page 7: ...7 ELECTRICAL WIRING DIAGRAM IMIX 3S 36526 040706 LEFT LAMP RIGHT LAMP ...

Page 8: ...WHI GRN BLK BLU BLK WHI RED WHI BLK BLK WHI RED RED RED ORN YEL BLU BRN BLK BRN WHI RED WHI ORN WHI YEL WHI BLU GRN BLK RED WHI BLU RED BLK RED WHI WHI GRN BLU RED LAMP 1 BALLAST LAMP 2 BALLAST BLK BLK BLK BLK BLK BLK BLK BLK BRN BLK HOPPER 4 HOPPER 5 M M M SOL M SOL M SOL M SOL M SOL STATION 1 WHIPPER STATION 2 WHIPPER STATION 3 WHIPPER STATION 4 WHIPPER STATION 5 WHIPPER STATION 1 DISPENSE VALVE...