3.  Press and release the center button once more. The display will read 

H2

, then show 

either 

FAH

 (Degrees in Fahrenheit) or 

Cen

 (Degrees in Centigrade).

4.  Use the (+) and (-) buttons to alternate between 

FAH

 and 

CEn

.

5.  Press and release the center button once more. The display will read 

H3

, then show 

(- - -)

.

6.  Press and hold both (+) and (-) buttons to initiate the resetting of the factory de-

fault settings. The display 

(- - -)

 will fl ash on and off during this time (about 5 to 7 

seconds).

7.  When the factory default numbers are loaded in, the display will stop fl ashing, then 

read 

don

 (DONE). You can now release the two buttons.

NOTE: If you release the two buttons at any time before the display reads 

don

, the Factory Default numbers will 

not be entered. The old numbers will remain in the memory.

8.  To exit Level 2 Program press and release the center button once more. The display will read 

(-)

.

ADJUSTING DISPENSE VOLUMES

NOTE:

 The dispenser should be at operating temperature before setting dispense volumes.

1.  Press and hold the hidden programming button, located under the ® next to the BUNN logo on the front of 

the dispenser until the 3 LED's begin fl ashing from the left to the right. Release the button.

2.  Place an empty graduated container under the dispense nozzle.
3.  Press and release the batch size to be set. The LED's will stop fl ashing, and the LED over the button just 

pressed will come on solid. Water will begin to dispense into the container.

4.  When the desired amount of water is dispensed, press and release the same button. The water will stop 

dispensing and the batch size is now set.

5.  The LED's will begin fl ashing from left to right again. Repeat steps 2 thru 4 to set up the other batch sizes.
6.  To exit the programming set up at any time, press and release the hidden button once. The dispenser is now 

ready for use.

39338 100606

Summary of Contents for H5E-DV PC

Page 1: ...it the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the catalog Contact Bunn O Matic Corproation at 1 800 286 6070 to obtain a paper copy of the required...

Page 2: ...authorized BUNN service location and 3 receiving prior authorization from BUNN that the defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY...

Page 3: ...3 WARNING Very Hot Water Use With Care...

Page 4: ...re the toggle switch below the circuit board is set to the desired voltage 120 volts or 208 240 volts and the red switch on the circuit board is in the SET position Fig 2 6 Install a strain relief and...

Page 5: ...countertop It can be purchased direct from Bunn O Matic part number 00326 0000 Bunn O Matic does not recommend the use of a saddle valve to install the dispenser The size and shape of the hole made i...

Page 6: ...ource throughout these steps 1 Disconnect the dispenser from the power source 2 Shut off and disconnect the incoming water supply 3 Remove the 4 40 screws at the sides of the top panel 4 Gently remove...

Page 7: ...ount of water to be dispensed Pressing a different button after a cycle has been initiated does not change the volume in progress b AUTO STOP MANUAL DISPENSE BUTTON Press and release button to stop a...

Page 8: ...utton to increase the temperature set point and the button to de crease the set point 3 Press and release the center button once more The display will read P2 then show the ready temperature set point...

Page 9: ...e the center button once more The display will read ADJUSTING DISPENSE VOLUMES NOTE The dispenser should be at operating temperature before setting dispense volumes 1 Press and hold the hidden program...

Page 10: ...14 WHI VIO 14 VIO 18 BLK 18 WHI BLU 18 WHI 18 4000 W TANK HEATER L2 N MASTER ON OFF SWITCH BLK 14 RED 14 SCHEMATIC WIRING DIAGRAM H5E DV PC BLU 14 SELECTOR SWITCH BLK 14 LIMIT THERMOSTAT OVERFLOW PRO...

Reviews: