![Bunn Crescendo Series Installation & Operating Manual Download Page 25](http://html1.mh-extra.com/html/bunn/crescendo-series/crescendo-series_installation-and-operating-manual_2830874025.webp)
25
042319
Weekly: Parts Washing and Sanitizing
Rinse cleaning brush, dip in sanitizing
solution, and brush the bore of both
dispense nozzles.
NOTE
: Repeat this procedure for
each nozzle separately.
Remove dispense hoses from dispense
nozzle assembly.
Prepare one-gallon (3.8 liter) of sanitizing
solution with at least 100 ppm of available
chlorine in 120°F (48.9°C) water. Soak all
cleaned parts in sanitizing solution for 5
minutes, then allow to air dry.
Rotate tab on mixing chamber
base further counter clock wise,
and remover from shaft by pulling
straight out.
NOTE
: Ensure O-ring and shaft seal
are in place during re-assembly.
Remove right frother disk from
shaft by pulling straight out.
Remove elbows from right & left
mixing chambers, twisting slightly
to help release.
Remove elbows from all hoppers.
When reassembling parts, be sure to
align arrow on frother disk with flat on
whipper motor shaft, and rotate tab on
whipper base clock wise to the vertical
position to lock mixing chamber.
Rotate tab at bottom of mixing
chamber bases counter clock
wise to release base.
Remove mixing chambers by pull-
ing straight out.
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 6
STEP 7
STEP 8
STEP 9