BUNN
®
practices continuous product research and improvement. We reserve the right to change specifications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
All dimensions shown in inches.
Bunn Corporation owns all copyrights relating to materials in this publication. Please contact Bunn Corporation to request permission to reproduce any portion of this publication.
Dimensions & Specifications
BUNN Corporation - 1400 Stevenson Drive Springfield, Illinois 62703 • 800-637-8606 • 217-529-6601 • Fax 217-529-6644 • www.bunn.com
8.50
21.40
Model
Product #
Volts Amps Tank Heater Total
Brewing
Cu.
Shipping
Cord
Watts
Watts
Capacity
Ft.
Weight
Attached
CDBCF-DV (2 top) 28800.0230
120
15
1425
1800
4.5 gal./hr.
4.0
30 lbs.
No
120/208 15.6
2629
2980
7.5 gal./hr.
120/240 17.5
3501
3850
7.5 gal./hr.
CDBCF-DV (2 top)* 28800.0231
120
15
1425
1800
4.5 gal./hr.
4.0
31.2 lbs.
No
120/208 15.6
2629
2980
7.5 gal./hr.
120/240 17.5
3501
3850
7.5 gal./hr.
*Model has a stainless steel funnel.
Brewing capacity:
based upon incoming water temp of 60ºF (140ºF rise) per 1/2 gallon brew time of 4 minutes.
Electrical: 120 volt, 15 amp. models require 2-wires plus ground service rated 120V, single phase, 60 Hz.
An internal terminal block is configured for connection to a 3-wire plus ground.
Plumbing: 20-90 psi (138-621 kPa). Machines supplied with
1
⁄
4
" male flare fitting. Twin models supplied with
3
⁄
8
" male
flare fitting.