SERVICE (cont.)

VACUUM/SUPPLY PUMP ASSEMBLY

FIG. 16 VACUUM/SUPPLY PUMP ASSEMBLY

P1560

Location:

 

The vacuum/supply pumps are located inside 

the autofill box.

Test Procedure:

1.  Disconnect the dispenser from the power source.

2.  Disconnect the white wire from the pump lead and 

the yellow, orange or red wire from the other lead.

3.  Check the voltage across the white wire and yellow, 

orange or red wire with a voltmeter. Connect the 

dispenser to the power source. Push the pump 

(flavor) switch for the pump to be tested. The 

indication must be :

 

a) 120 volts ac for two wire 120 volt models.

 

b) 200 to 240 volts ac for two wire 200 or 240 volt 

models.

If voltage is present as described, replace the pump.

If voltage is not present as described, refer to the 

wiring diagrams and check the main wiring harness.

Pump Removal and Replacement:

1.  Disconnect the wires from the pump leads.

2.  Disconnect the input and output tubes.

3.  Remove the four thumb screws securing the pump 

head to the pump body, discard pump head with 

tubes.

4.  Remove the two #8-32 keps nuts securing the 

pump to the main mounting panel.

5.   Remove the two #6-32 screws securing the pump 

body to the mounting bracket.

6.  Remove pump body and discard. 

7.  Install new pump assembly on the pump mounting 

bracket and secure with two #6-32 screws.

8.  Remove the four thumb screws securing the  new 

pump head  with hoses to the new pump body.

9.  Using two #6-32 screws mount the pump body 

on the pump mounting bracket.

10. Using two #8-32 keps nuts mount the pump body 

and bracket to main panel.

11. Install new pump head with hoses to the rear of the 

pump body and secure with four thumb screws.

12. Connect the input and output tubes using new 

hose  clamps.

13. Refer to Fig 17 and reconnect the wires.

WHI from Main Harness

YEL from Pump Switch #1

WHI from Pump #1

ORN from Pump Switch #2

WHI from Pump #2

RED from Pump Switch #3

FIG. 17 VACUUM/SUPPLY PUMP TERMINALS

P1526

28791.1 011500

Summary of Contents for AF PR-2

Page 1: ...CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 28791 0001B 1 00 1998 Bunn O Matic Corporation AF PR 2 AF PR 3 AFPR 3 VERSION DISCONTINUED The info...

Page 2: ...cations to this warranty or to make additional warranties that are binding on Bunn Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be rel...

Page 3: ...switches high level low level and a center OFF position 7 Place the main ON OFF switch and ON OFF refill switches in the OFF position 8 Make sure all hoses are connected Connect the dispenser to the...

Page 4: ...y TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered If the problem remains after exhausting the troubleshooting steps...

Page 5: ...the main power switch These allow each circuit to operate independently of the other P2052 C PROBE CONTROL BOX LOW OFF HIGH On models equipped with a dual level probe there is a LOW OFF HIGH switch l...

Page 6: ...Fuse Holder for test procedures See page 8 Refer to Service Main ON OFF Switch for testing procedure See page 9 Refer to Service Probe System See page 10 Refer to Service Circuit Board for testing pro...

Page 7: ...es to plug in the dispenser COMPONENT ACCESS WARNING Disconnect the dispenser from the power source before the removal of any panel or the replace ment of any component All components are accessible b...

Page 8: ...BOARD P1556 O F F O N O F F O N O F F O N SERVICE Location The circuit board is located inside the autofill box mounted on the right side of the vacuum switch mounting Test Procedure 1 Disconnect the...

Page 9: ...lace the fuse 28791 1 011500 BLK from Main Wiring Harness BLK to Main ON OFF Switch FIG 5 FUSE HOLDER TERMINALS P1331 Removal and Replacement Fuse 1 Remove the cap from the fuse holder 2 Removefusefro...

Page 10: ...o the main ON OFF switch Disconnect the white wire from pump 1 3 Check for voltage across the black wires removed from the switch and the white wire removed from pump 1 Connect the dispenser to the po...

Page 11: ...oss the signal cable pins see Fig 8A 6 If readings match values indicated the probe system electrically is functioning properly If not check the probe boxes 5 With the probe box switch in the LOW posi...

Page 12: ...diagrams and check the dispenser wiring harness 5 Check for continuity across the switch terminals with the switch in the ON position Continuity must not be present when the switch is in the OFF posi...

Page 13: ...from the pump leads 2 Disconnect the input and output tubes 3 Removethefourthumbscrewssecuringthepump head to the pump body discard pump head with tubes 4 Remove the two 8 32 keps nuts securing the pu...

Page 14: ...p head cavity 4 Push down and turn the key counterclockwise to guide the tubing deep into the pump head cavity as shown in Fig 19 5 Hold the tubing and rotor in the pump head and remove key carefully...

Page 15: ...32 keps nuts securing the pump and bracket to main panel 5 Disconnect the yellow and white wires from the pump 6 Remove pump and bracket as an assembly 7 Disconnecttheinputtubesfromthevacuumswitch to...

Page 16: ...16 28791 1 011500...

Page 17: ...17 28791 1 011500...

Reviews: