24
AUGER MOTOR CAPACITOR
FIG. 3 AUGER MOTOR CAPACITORS
P1341
Location:
The auger motor capacitor(s) are located on the lower right
side of the auger motor mounting bracket inside the auger
motor cover(s).
Test Procedures
1. Remove the hopper from the same side as the motor
to be tested.
2. Turn “ON” the appropriate auger switch.
3. Nudge the auger to start it turning.
If the auger doesn’t turn, replace the motor.
If auger starts to turn, replace the start capacitor.
WARNING:
The compressor start capacitor must be properly
discharged before removing. This is most commonly done
on low voltage capacitors by shorting across the terminals
with a screwdriver.
Removal and Replacement
1. Remove the two #8 locking screws securing the
auger motor cover to the cooling drum mount assy.
2. Remove the cover and set aside for reassembly.
3. Disconnect the wires from the auger motor capacitor
terminals.
4. Remove the #8 locking screw on the lower right side
of the auger motor mounting bracket securing the
auger motor capacitor.
5. Install a new capacitor on the lower right side of
the auger mounting bracket and secure with a #8
locking screw.
6. Reconnect the wires to the capacitor terminals.
7. Refer to Fig. 4 when reconnecting the wires.
LEFT MOTOR CAPACITOR
BRN/WHI to Left Auger Motor J13-2
BRN/BLK to Control Board J13-3
RIGHT MOTOR CAPACITOR
WHI/RED to Right Auger Motor J13-13
RED/BLK to Control Board J13-1
SERVICE (continued)
FIG. 4 AUGER MOTOR CAPACITOR TERMINALS