Remove the motor cover
Secure the structure and
motor to the ceiling
Assemble the motor cover
Fit the drying rack
Wiring BUNGY
Screw the remote control
to the wall
Unscrew the motor cover.
Place the metal structure with the motor by aligning
its holes with the holes in the ceiling.
Place and tighten the screws in the order shown in
the image.
Place the motor cover and tighten the two screws.
Connect BUNGY to power respecting the color code:
Blue - neutral; Brown - live; Green and yellow - Earth
Secure the remote control wall bracket in an
appropriate location with the supplied screw.
Fix the hanger to the strips with the supplied screws
and nuts.
3.
6.
5.
4.
7.
8.
WARNING: The gray and black conductors
should not be used, must be isolated and
can not be connected to electricity.
1
2
3
4