Figure 18: Different Manufacturer’s Zone Valve Connections to Honeywell R8889
NOTICE
The H oneywell R888 9 Control is ava ilable in two three (3) zone mode ls and two four (4) zone
models. Burnha m recommends using M ode l R88 89A for three (3) zone sys tems and Model
R888 9B for four (4) z one systems. M ode ls R88 89C a nd R 8889D have le ss load capac ity and may
not operate w ith certain types of zone v alves. U p to four (4) R 8889's may be used together to
provide up to sixtee n (1 6) individual z ones. Only one (1 ) z one, the first zone of the main control
will provide priority z oning for the Alliance indire ct water heater. If more than four (4 ) z ones are
required, c onne ct additional R8889's by wiring the A , B and C terminals of each control
together. Eac h R 8889 requires a 120 volt power supply. If more than one (1) R8889 is us ed, set
the panel type sw itch to "ma in" on the first R 8889 a nd s et the panel type sw itch to "e xpansion"
on the second, third or fourth R88 89.
Summary of Contents for RSA
Page 11: ...11 Figure 6 RSA Jacket Assembly ...
Page 14: ...14 Figure 8 Recommended Boiler Piping for Circulator Zoned Heating Systems ...
Page 15: ...15 Figure 9 Boiler Piping for Zone Valve Zoned Heating Systems ...
Page 22: ...22 Figure 16 Circulator Zoned Wiring for Honeywell R8888 ...
Page 23: ...23 Figure 17 Zone Valve Zoned Wiring for R8889 ...
Page 26: ...26 Figure 19 Circulator Zoning with EC5000 Wiring Schematic ...
Page 27: ...27 Figure 20 Zone Valve Zoned with EC5000 Wiring Schematic ...
Page 43: ...43 SERVICE SCHEDULE DATE SERVICE PERFORMED ...
Page 45: ...45 Ordering Information for Quality Replacement Parts Figure 29 BECKETT AFG MODEL BURNER ...
Page 48: ...48 ...