MY22B01 - 12_1.0_26.08.2021
208
Technical inspection, checking safety, test ride
Inspection
Tests
Maintenance
Accept-
ance
Rejection
Electric drive
On-board
computer
6 months
Check for damage
Functional check
O.K.
No screen,
defective
screen display
Restart, test battery,
new software or new
on-board computer;
take out of service
Electric drive
control panel
6 months
Drive Check for
damage
Functional check
O.K.
No response
Restart; contact
control panel
manufacturer, new
control panel
Tachometer
6 months
Speed
measurement
O.K.
Pedelec
travelling 10 %
too fast/slow
Take pedelec out of
service until the
source of the error is
found
Cabling
6 months
Visual inspection
O.K.
Failure in sys-
tem, damage,
kinked cables
New cabling
Battery mount
6 months
Firmly in position,
lock, contacts
Functional check
O.K.
Loose; lock
doesn't close,
no contacts
New battery mount
Motor
6 months
Visual inspection and
mount
O.K.
Damage,
loose
Refasten motor;
contact motor
manufacturer, new
motor;
take out of
service
Software
6 months
Check version
In latest
version
Not latest
version
Import update
Components
Frequency
Description
Criteria
Measures if
rejected
Components
Description
Criteria
Measures if rejected
Assembly/inspection
Tests
Accept-
ance
Rejection
Brake system
6 months
Functional check
O.K.
No full braking; braking
distance too long
Locate defective part in brake
system and correct
Gear shift under
operating load
6 months
Functional check
O.K.
Problems when shifting
gear
Readjust gear shift
Suspension
components (fork,
shock absorber, seat
post)
6 months
Functional check
O.K.
Suspension too deep or no
longer exists
Locate defective component and
correct
Electric drive
6 months
Functional check
O.K.
Loose connection,
problems when riding,
accelerate
Locate defective part in electric
drive and correct
Lighting system
6 months
Functional check
O.K.
No continuous light, not
bright enough
Locate defective part in lighting
system and correct
Test ride
6 months
Functional check
No strange
noises
Strange noises
Locate source of noise and
correct
Date:
Fitter's name:
Final inspection by workshop
manager
Summary of Contents for 22-15-1078
Page 210: ...MY22B01 12_1 0_26 08 2021 209 Notes ...
Page 217: ...MY22B01 12_1 0_26 08 2021 216 Documents D Compact Charger A G A C EBE D F ...
Page 218: ...MY22B01 12_1 0_26 08 2021 217 Documents D EBE D F A G A C ...
Page 219: ...MY22B01 12_1 0_26 08 2021 218 Documents D A G A C EBE D F ...
Page 220: ...MY22B01 12_1 0_26 08 2021 219 Documents D EBE D F A G A C ...
Page 229: ...MY22B01 12_1 0_26 08 2021 228 Appendix II Declaration of conformity for incomplete machine ...
Page 230: ...MY22B01 12_1 0_26 08 2021 229 Appendix ...