5.Warning Information

a.

       

Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

b.

       

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

c.

       

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.

d.

       

Children should be supervised to ensure that they do not play with the appliance.

e.

       

Details concerning cleaning and other maintenance

f.

 

Maintenance of water purity, especially PH values and chlorine concentrations.

g.

       

Cleaning and disinfection

h.

       

Use and installation of a cover.

i.

 

Disposal of water

j.

 

Precautions to avoid damage due to water freezing

k.

       

Precautions to avoid damage when the appliance is left empty for extended period.

     
     

2.2 Sub-clause 7

     The installation instruction shall state the substance of the following:

-

   

Earthed appliances must be permanently connected to fixed wiring;

-

   

The appliance should be supplied through a residual current device (RCD) having a rated residual 

operating current not exceeding 30 mA.

-

   

The floor has to be capable of supporting the expected load.

-

   

An adequate drainage system has to be provided to deal with overflow water.

-

   

Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone 

and that equipotential bonding is carried out.

WAR

NING

1

DANGER

RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a

Ground Fault Circuit lnterrupter.

2

Grounding is required. The unit should be installed by a qualified service representative and

ground.

3

FOR YOUR SAFETY-This product should be installed by a professional service 

   technician,qualified in hydrotherapy bath installation.
4

lt’s prohibited to cover the instrument with something while opeating.

5

when using at the first time ,Be sure there is water in heater pipe before staring.

6

parts containing live parts, except parts upplied with safety extra-low voltage not  Exceeding

12V,must be inaccessible to person in the bath

8

earthed appliances must be permanently connected to fixed wiring

9

the appliance should be supplied through a residual current device (RCD)having a rated

residual operating current not exceeding 30 mA.

1

0 、

If  the mains cord of this appliance is damaged,It must only bereplaced  by our service

representative,As special tools and/or parts are required

11

Summary of Contents for SPA-562

Page 1: ...HOT TUB Model SPA 562 OPERATING INSTRUCTION 1...

Page 2: ...itch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump 2 On off Lasting Circulation Cleaning On off Surfing pump circulalt...

Page 3: ...eration Fig 3 Normal Temperature Display Fig 4 Senor on short circuit Display 1 When you first turn on the spa the backlight control panel is dim and LCD shows current time and temperature If spa happ...

Page 4: ...ation cleaning on Pre circulation cleaning Setting should be under the power off status just turn on the spa LCD will display 1 Press to start Circulation cleaning setting mode LCD showes and it is fl...

Page 5: ...ress to confirme all settings Notice The system will be exit automatically by pressing key of 1 Pre circulation setting be turn off 2 starting time of circulation 3 Lasting time of circulation 4 Finis...

Page 6: ...t the time It will be added 1 hour when pressing HOUR each time and hours could be added continually when pressing the HOUR without stopping The adjustment of hours is 00 23 It will be added 1 minute...

Page 7: ...2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time reaches your desired time heater will work If panel shows off means that heater not be set 3 Circu...

Page 8: ...works at the same The LCD shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozonier works at every 15 minutes The circulation cleaning will be...

Page 9: ...ill display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max is 10 Name o...

Page 10: ...wer 16 Fahrenheit Celsius Temperature shift In the status of Power off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All surfing pumps and heat...

Page 11: ...gh a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage system has to be provide...

Page 12: ...a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug...