background image

(5)

2.1 Attach the Power Cord

2.2 Install the Brush or Pad Driver

The triple-wire grounded power cord has been
factory-installed into the handle tube. Plug the male
connector (9) coming out of the motor housing into
the female connector (10) coming out of the end of
the handle tube.

Now, plug the end of the 50 foot power cord into a
grounded power outlet.

queeze both triggers on the handle

and check for power to the motor.

Your floor machine has been built with a “B” style
drive plug fixed to the motor shaft. A brush or pad
driver mounts onto the machine using a
“B” style or a “ Universal” plate on the
brush block

Unplug the floor machine. Lock the
machine handle in the “up” position
and tip the floor machine back
onto the handle.

Mount the brush or pad driver with
the clutch plate(11) over the
drive plug (12).

Give the brush a quick spin to lock the brush
onto the floor machine.

Now, lower the machine back onto the brush.
You’re ready to go to work.

Push the red safety interlock

switch forward to unlock the dual triggers. Hold the
handle firmly, s

!

!

!

!

10

12

11

9

(4)

This floor machine is shipped from the factory with the handle
unattached. You will need two 7/16” wrenches to complete the
assembly.

Remove the handle and mounting hardware from its carton. Bolts,
nuts, washers and the locking lever assembly are in the plastic bag
attached to the handle.

Align the handle with the yoke (1) over

the mount (2) on the buffer chassis. The
power cord will be facing the motor.
Place a flat washer (4) on a 3” bolt (3),
then place the bolt through the holes in
the yoke and the mount. Place another
washer on the bolt and secure with the
locking nut (5).

Tip the handle up. The handle mounting

collar (7) is designed to slide freely up and
down the handle tube, allowing the handle
to be adjusted for the comfortable
operation of all users. Line up the
mounting collar with the upper holes in the
two bent handle braces (6).

1.

Mount the handle on the chassis.

2.

Mount the support braces to the

handle.

Place the curved spacer (12) with a

square hole onto the locking lever shaft
(11). The curve must face the lever, as in
the picture at right.

Insert the shaft through the upper hole in

the left handle brace (6), mounting collar
(7), and right handle brace.

Place a spacer (9) on the shaft.
Place the split washer (10) on the shaft
Place the locking wing nut (13) on the shaft.
Tighten and adjust the wing nut. When correctly installed, the

collar slides easily when the cam-engineered locking lever is
“up”, but is firmly fixed when the lever is “down”.

!

!

!

!

!

!

3

1

1

4

4

2

2

5

13

10

7

11

6

9

12

2.0 Mount the Handle

Summary of Contents for BDP-15D

Page 1: ...cts walls and baseboards Fully adjustable handle position comfortable for all operators Non marking retractable 6 wheels for easy transport BULLDOG General Duty Floor Machine 175 RPM 1 HP 15 17 and 19 Safety enhanced non conductive dual triggers eliminates shock potential Safety enhanced interlock switch both hands are conveniently in control For medium duty polishing and scrubbing Precision balan...

Page 2: ...ive equipment over it or run the floor machine over it Do not exposing the cord to hot surfaces Never operate the floor machine over sharp objects that can be thrown out and harm the operator and damage the floor Sweep before scrubbing or buffing NO NO NO YES NO NO NO NO NO 2 1 1 Electric Power This floor machine operates on a 15 amp nominal 120V 60 hz A C power circuit The amp hertz and voltage r...

Page 3: ...te the assembly Remove the handle and mounting hardware from its carton Bolts nuts washers and the locking lever assembly are in the plastic bag attached to the handle Align the handle with the yoke 1 over the mount 2 on the buffer chassis The power cord will be facing the motor Place a flat washer 4 on a 3 bolt 3 then place the bolt through the holes in the yoke and the mount Place another washer...

Page 4: ...Test the outlet with a ground fault interrupter Retain a certified electrician to inspect and repair grounding NEVER clip off the ground plug on your cord High amp draw and circuit breaking can be an electrical or mechanical problem Seek authorized repair service Tip machine back and re center the pad Replace Replace 3 2 Transport For indoor use only Sweep abrasive soils before scrubbing While the...

Page 5: ...rs As aggressive as a red scrub pad is a 0 022 filament with 120 grade grit For aggressive scrubbing and light stripping of resilient floors terrazzo and concrete As aggressive as a blue scrub pad is a 0 050 filament with 80 grade grit For very aggressive scrubbing and stripping of concrete brick and quarry tile As aggressive as a black pad 5 1 Scrubbing Brush Filaments 5 0 Brush and Pad Construct...

Page 6: ...7 Int Tooth Lock Washer For Switch B 35 1 28 Insulated Flag Wire Connector G 48 2 29 On Off Switch And Plate Assembly G 30 AB 1 30 Lock Washer B 33 1 31 Trigger Return Spring G 30 CT057 1 32 Label For Switch Box CALL FOR 1 33 Switch Box Front A 103 1 34 Wire Connector G 47 1 35 Trigger A 105 2 36 16 Crossbar M 211 A 1 37 Safety Interlock Assembly SIA 1 1 38 Trigger Pin B 70 2 39 Crossbar Screw B 2...

Page 7: ...all Mercury floor machines to be free from defects in material and workmanship under normal use and service for five 5 years to the original purchaser Parts replaced or repaired under this warranty are warrantied for the remainder of the original warranty period Service labor charges are covered for up to one 1 year from the date of purchase through an authorized Mercury Floor Machine service prov...

Reviews: